Page 15 - Wilger Catalog
P. 15

 COMBO-JET 80° Spray Tips - Standard Sprayer Systems Comprehensive rate & speed charts for any nozzle spacing/speed/rate is available on Tip Wizard. Try it today!
NO
! Disclaimer: These charts are published for comparative purposes to demonstrate the differences in the series of Combo-Jet® spray tips. Data used to populate this chart is extrapolated from third party testing data from a controlled conditions test with water as the testing solution. Actual spray applications with active chemical ingredients may change the spray dynamics and spray tip performance specifications. Wilger is not liable for any misuse or misrepresentation of this information, leading to (but not limited to) incorrect spray application, crop damage, or any other harm. (Not limited to human, livestock or environmental). Always verify these charts with the most recent charts found on the www.wilger.net, and ALWAYS follow chemical label nozzle requirements.
Z Z
Nozzle Flow Angle & Rate
Boom Application Rate in US Gallons / Acre on
Pressure 20” Nozzle Spacing @ Sprayer Speed (mph) ER80° Series
SR80° Series Class VMD <141 <600
MR80° Series DR80° Series Class VMD <141 <600 Class VMD <141 <600 MR80-005 (40290-005) DR80-005 (40280-005) Class VMD <141 <600 Class VMD <141 <600
M 261 11% 99% C 311 6% 100% M 236 17% 98% C 276 11% 100% M 217 22% 97% M 250 16% 100% F 201 26% 96% M 230 19% 100% F18930%95%F21323%100% F17833%94%F20025%100% F16139%93%F17830%100% F15441%92%F16933%100% F14844%91%F16135%100% F13848%90%F14838%100%
MR80-0067 (40290-007)DR80-0067(40280-007) Class VMD <141 <600 Class VMD <141 <600
M 231 18% 99% C 337 6% 100% F 211 24% 98% C 308 9% 100% F19529%97%C28511%100% F18233%96%M26713%100% F17137%95%M25215%100% F16240%94%M23917%100% F14846%93%M21820%100% F14249%92%F21021%100% F13651%91%F20222%100% F 127 55% 90% F 189 24% 100%
MR80-01 (40290-01) DR80-01 (40280-01) Class VMD <141 <600 Class VMD <141 <600
PSI Spraying with Auto-Rate Spray System Class VMD <141 <600 Boom Application Speed (mph) @ ER80-005 (40270-005) psi 2Gpa 3Gpa 4Gpa 5Gpa 6Gpa 7Gpa 8Gpa Class VMD <141 <600 0.035 20 5.3 3.5 2.6 2.1 1.8 1.5 1.3 F 167 33% 100% 0.040 25 5.9 3.9 2.9 2.3 2.0 1.7 1.5 F 157 40% 100% 80° 0.043 30 6.4 4.3 3.2 2.6 2.1 1.8 1.6 F 149 46% 100% -005 0.047 35 6.9 4.6 3.5 2.8 2.3 2.0 1.7 F 142 51% 100% 0.050 40 7.4 5.0 3.7 3.0 2.5 2.1 1.9 F 137 55% 100% 0.053 45 7.9 5.3 3.9 3.2 2.6 2.3 2.0 F 132 59% 100% 0.056 50 8.3 5.5 4.2 3.3 2.8 2.4 2.1 F 128 63% 100% 0.061 60 9.1 6.1 4.5 3.6 3.0 2.6 2.3 F 121 68% 100% 0.064 65 9.5 6.3 4.7 3.8 3.2 2.7 2.4 F 118 71% 100% 0.066 70 9.8 6.5 4.9 3.9 3.3 2.8 2.5 F 116 73% 100% 0.071 80 11 7.0 5.3 4.2 3.5 3.0 2.6 VF 111 78% 100%
Flow Boom Application Speed (mph) @ ER80-0067 (40270-007) us gpm psi 2Gpa 3Gpa 4Gpa 5Gpa 6Gpa 7Gpa 8Gpa Class VMD <141 <600 0.047 20 7.0 4.7 3.5 2.8 2.3 2.0 1.8 F 199 21% 100% 0.053 25 7.9 5.2 3.9 3.1 2.6 2.2 2.0 F 183 29% 100% 80° 0.058 30 8.6 5.7 4.3 3.4 2.9 2.5 2.2 F 171 35% 100% -0067 0.063 35 9.3 6.2 4.7 3.7 3.1 2.7 2.3 F 161 40% 100% 0.067 40 9.9 6.6 5.0 4.0 3.3 2.8 2.5 F 153 45% 100% 0.071 45 11 7.0 5.3 4.2 3.5 3.0 2.6 F 147 49% 100% 0.075 50 11 7.4 5.6 4.4 3.7 3.2 2.8 F 141 52% 100% 0.082 60 12 8.1 6.1 4.9 4.1 3.5 3.0 F 131 58% 100% 0.085 65 13 8.5 6.3 5.1 4.2 3.6 3.2 F 128 61% 100% 0.089 70 13 8.8 6.6 5.3 4.4 3.8 3.3 F 124 63% 100% 0.095 80 14 9.4 7.0 5.6 4.7 4.0 3.5 F 118 68% 100%
Flow Boom Application Speed (mph) @ ER80-01 (40270-01) us gpm psi 4Gpa 5Gpa 6Gpa 7.5Gpa 8Gpa 9Gpa 10Gpa Class VMD <141 <600 0.07 20 5.3 4.2 3.5 2.8 2.6 2.3 2.1 F 175 29%100% 0.08 25 5.9 4.7 3.9 3.1 2.9 2.6 2.3 F 164 35%100% 80° 0.09 30 6.4 5.1 4.3 3.4 3.2 2.9 2.6 F 156 41% 100% -01 0.09 35 6.9 5.6 4.6 3.7 3.5 3.1 2.8 F 149 45% 100% 0.10 40 7.4 5.9 5.0 4.0 3.7 3.3 3.0 F 143 49%100% 0.11 45 7.9 6.3 5.3 4.2 3.9 3.5 3.2 F 139 53% 100% 0.11 50 8.3 6.6 5.5 4.4 4.2 3.7 3.3 F 134 56% 100% 0.12 60 9.1 7.3 6.1 4.8 4.5 4.0 3.6 F 128 62% 100% 0.13 65 9.5 7.6 6.3 5.0 4.7 4.2 3.8 F 125 64%100% 0.13 70 9.8 7.9 6.5 5.2 4.9 4.4 3.9 F 122 66%100% 0.14 80 11 8.4 7.0 5.6 5.3 4.7 4.2 F 117 70%100% Flow Boom Application Speed (mph) @ ER80-015 (40270-015) us gpm psi 4Gpa 5Gpa 6Gpa 7.5Gpa 8Gpa 10Gpa 12Gpa Class VMD <141 <600 0.11 20 7.9 6.3 5.3 4.2 3.9 3.2 2.6 F 199 21% 100% 0.12 25 8.8 7.0 5.9 4.7 4.4 3.5 2.9 F 188 25%100% 80° 0.13 30 9.6 7.7 6.4 5.1 4.8 3.9 3.2 F 180 29% 100% -015 0.14 35 10 8.3 6.9 5.6 5.2 4.2 3.5 F 173 32% 100% 0.15 40 11 8.9 7.4 5.9 5.6 4.5 3.7 F 167 34% 100% 0.16 45 12 9.5 7.9 6.3 5.9 4.7 3.9 F 162 37% 100% 0.17 50 12 10 8.3 6.6 6.2 5.0 4.2 F 158 39% 100% 0.18 60 14 11 9.1 7.3 6.8 5.5 4.5 F 151 42% 100% 0.19 65 14 11 9.5 7.6 7.1 5.7 4.7 F 148 44% 100% 0.20 70 15 12 9.8 7.9 7.4 5.9 4.9 F 145 46% 100% 0.21 80 16 13 11 8.4 7.9 6.3 5.3 F 140 48% 100%
Flow Boom Application Speed (mph) @ ER80-02 (40270-02) us gpm psi 5Gpa 6Gpa 7.5Gpa 8Gpa 10Gpa 12Gpa 15Gpa Class VMD <141 <600 0.14 20 8.4 7.0 5.6 5.3 4.2 3.5 2.8 F 184 28% 100% 0.16 25 9.4 7.8 6.3 5.9 4.7 3.9 3.1 F 176 31%100% 80° 0.17 30 10 8.6 6.9 6.4 5.1 4.3 3.4 F 170 34% 100% -02 0.19 35 11 9.3 7.4 6.9 5.6 4.6 3.7 F 166 36% 100% 0.20 40 12 9.9 7.9 7.4 5.9 5.0 4.0 F 161 38%100% 0.21 45 13 11 8.4 7.9 6.3 5.3 4.2 F 158 40% 100% 0.22 50 13 11 8.9 8.3 6.6 5.5 4.4 F 155 42% 100% 0.24 60 15 12 9.7 9.1 7.3 6.1 4.8 F 150 45% 100%
Sizes USGPM
Flow us gpm
Nozzles
Nozzles
Nozzles
Nozzles
M 233 29% 97%
F 214 29% 97%
F 199 29% 97%
F 186 29% 97%
F 176 29% 98%
F 159 29% 98%
F 152 29% 98%
F 146 29% 98%
F 135 29% 98% F 139 48% 97% F 202 23%102%
Nozzles
Flow Boom Application Speed (mph) @ ER80-025 (40270-025) us gpm psi 5Gpa 6Gpa 7.5Gpa 8Gpa 10Gpa 12Gpa 15Gpa Class VMD <141 <600 0.18 20 11 8.8 7.0 6.6 5.3 4.4 3.5 M 232 17% 100% 0.20 25 12 9.8 7.8 7.3 5.9 4.9 3.9 M 219 21%100% 80° 0.22 30 13 11 8.6 8.0 6.4 5.4 4.3 F 209 23% 100% -025 0.23 35 14 12 9.3 8.7 6.9 5.8 4.6 F 200 26% 100% 0.25 40 15 12 9.9 9.3 7.4 6.2 5.0 F 194 28% 100% 0.27 45 16 13 11 9.8 7.9 6.6 5.3 F 188 30% 100% 0.28 50 17 14 11 10 8.3 6.9 5.5 F 182 31% 100% 0.31 60 18 15 12 11 9.1 7.6 6.1 F 174 34% 100% 0.32 65 19 16 13 12 9.5 7.9 6.3 F 170 36% 100% 0.33 70 20 16 13 12 9.8 8.2 6.5 F 167 37% 100%
SR80-015 (40288-015) Class VMD <141 <600
C 286 13% 94% M 262 16% 95% M 244 19% 96% M 230 22% 96% M 218 24% 97% F 207 26% 97% F 191 30% 97% F 184 32% 97% F 177 33% 98% F 167 36% 98% SR80-02 (40288-02)
Class VMD <141 <600
C 273 13% 94% M 257 16% 95% M 244 18% 96% M 233 20% 96% M 224 22% 97% M 216 24% 97% F 203 27% 98%
MR80-015 (40290-015) DR80-015 (40280-015) Class VMD <141 <600 Class VMD <141 <600
C 323 10% 94% VC 418 4% 87% C 301 12% 95% VC 397 5% 89% C 283 14% 96% C 380 6% 90% M 269 16% 97% C 365 6% 91% M 256 17% 97% C 353 7% 92% M 236 20% 98% C 332 8% 94% M 227 21% 98% C 324 8% 94% M 220 22% 99% C 316 9% 95% F 207 23% 99% C 302 10% 95%
MR80-02 (40290-02) DR80-02 (40280-02) Class VMD <141 <600 Class VMD <141 <600
C 326 8% 94% XC 454 3% 80% C 310 10% 94% VC 435 4% 83% C 298 11% 94% VC 419 4% 84% C 287 13% 94% VC 406 5% 86% C 277 14% 95% VC 394 5% 87% M 262 16% 95% C 375 6% 88% M 255 17% 95% C 366 6% 89% M 249 17% 95% C 359 7% 90%
Nozzles
SR80-025 (40288-025) Class VMD <141 <600
C 315 9% 91% C 296 11% 93% C 281 13% 94% M 268 15% 94% M 257 17% 95% M 248 18% 95% M 233 20% 96% M 226 21% 96% M 221 22% 97%
MR80-025 (40290-025) DR80-025 (40280-025) Class VMD <141 <600 Class VMD <141 <600
VC 425 5% 81% XC 460 3% 77% VC 401 6% 83% VC 443 4% 79% C 382 6% 85% VC 430 4% 81% C 367 7% 86% VC 418 5% 82% C 353 8% 87% VC 408 5% 83% C 330 9% 89% C 391 6% 85% C 321 10% 89% C 383 6% 85% C 312 10% 90% C 377 7% 86% C 297 11% 91% C 365 7% 87%
Spray Classification, VMD (Droplet Size in μ); %<141μ (Drift %); %<600μ (Small Droplets)
E S
0.25 65 15 13 10 9.5 7.6 6.3 5.0 F 147 46% 99% F 198 29% 98%
0.26 70 16 13 10 9.8 7.9 6.5 5.2 F 145 47% 99% F 193 30% 98%
0.28 80 17 14 11 11 8.4 7.0 5.6 F 142 49% 99% F 184 32% 98% M 239 19% 95% C 346 7% 91%
0.35 80 21 18 14 13 11 8.8 7.0 F 161 39% 99% F 211 24% 97%
NOTE: 1SR, MR, DR, UR spray tips include pre-orifice(s). Pre-orifices are not interchangeable between different spray tips of different series. 2Shown application information is based on water @ 80°F in a controlled environment and
should not be considered actual. Information is provided for comparison to other Combo-Jet® spray tips, for educational purposes only. Repeat testing results can vary.
Wilger Catalog - Updated January 2022
15
Distributed By: Sensor-1 • 202 Main Street, Princeton, KS 66078 • 1-800-SENSOR-1
SR80-01 (40288-01) Class VMD <141 <600 C 292 29% 97% M 258 29% 97%
M 218 23% 97% C 312 10% 94% F 204 27% 97% C 291 12% 95% F 191 30% 97% C 274 14% 96% F 181 33% 97% M 260 15% 97% F 173 36% 97% M 248 17% 98% F 159 40% 97% M 229 19% 99% F 153 42% 97% M 221 20%100% F 148 44% 97% F 214 21%101%
OZ
Z
L
LS
N
E

































   13   14   15   16   17