Page 91 - Demo
P. 91

  Strain measuring instruments - Dynamic measurements
 DIGITAL DYNAMIC STRAINMETER
   Type No. of channels
DRA-162B 16
DS-50A 50
DC-204R 4 DC-204Ra 4
DC-004P 4
DH-14A 4
DRA-30A 30
Bridge Voltage
Frequency Response
Interface
DRA-162B DS-50A
 0.5, 2Vrms
DC2V
DC0.5, 2V DC0.5, 2V
DC0.5, 2V
DC0.5, 2V
DC2V
5kHz
DC ~ 2.5kHz LAN
DC ~ 100Hz LAN
    DC ~ 10kHz DC ~ 10kHz
USB
DRA-30A
DH-14A
DC-204R
DC-004P
  DC ~ 2kHz USB
DC ~ 1kHz _
    DC ~ 3kHz
USB GP-IB
 ANALOG DYNAMIC STRAINMETER
   Type No. of channels
DA-17A 1
DA-18A 1
DA-37A 1
DA-38A 1
DC-96A 1
DC-97A 1
Bridge Voltage
0.5, 2Vrms 5kHz
0.5, 2Vrms 5kHz
0.5, 2Vrms 20kHz
0.5, 2Vrms 20kHz
DC0.5, 1, 2, 5, 10V
DC0.5, 1, 2, 5, 10V
Frequency Response
DC ~ 2.5kHz
DC ~ 2.5kHz
DC ~ 10kHz
DC ~ 10kHz
DC ~ 200kHz
DC ~ 500kHz
DA-17A
Bridge Box 1-ch use
DA-18A
DC-96A
DC-97A
        2-ch use
Carrying Case housing 4-/6-/8-ch
Mounting Rack housing 10-ch
     8-ch use
    MULTI-RECORDER TMR-200 SERIES
 A small multi-channel data acquisition system offering easy combination of various sensor input according to measurement purpose.
 Measuring units
Strain Full bridge unit TMR-221
Carrier type Strain unit TMR-223 Voltage/Thermocouple unit TMR-231
Voltage Output unit TMR-241 Telemetry I/F unit TMR-252
CAN/VOICE/GPS unit TMR-251
Digital I/O unit TMR-253
Charge amplifier unit TMR-261
    OPTION
HISTOGRAM ANALYSIS LIBRARY TMR-211-01
By installing the TMR-211-01 software in the control unit TMR-211, the function of a histogram recorder can be added to the TMR-200 system.
TMR-7630H (Frequency analysis)
The frequency process and S-N analysis of expanded channels for later frequency analysis of the measured dynamic waveform are possible.
Strain 1G2G4G unit
TMR-222
      Dynamic Measurement Software
DRA-7630/DC-7630/TMR-7630/DS-7640
   Waveform Display Software WF-7630
for TML Dynamic Measurment Software Data
  •Data monitorings with various styles are possible.
•Graphics in versatile formats includ- ing spectrum graphs are possible.
•Rectangular rosette analysis and various numerical operations are possible using expanded channels
•Performs a unified control of condi- tion setting and data.
    •Separated files created by free run measurment are merged into one file.
•Cutting out and thinning are pos- sible during CSV conversion of data files.
•Several graphs and objects are arrenged in a graph windows.
•Image storage of graph data and CSV files storage of graph values are possible.
       89







   88   89   90   91   92