Page 18 - FORE JAMES DETAYLI 2018
P. 18

James Anchor

        Test System



                                                               Four Basic Capacities


                                                               The James Anchor Test system is available in light to
                                                               heavy duty versions as follows:

                                                               Standard Anchor Test System
                                                               Light Duty:      0-1200 lbs. Force (0-5 kN)
                                                                                40 lbs. (0.2 kN) gauge division
                                                               Medium Duty:  0-3600 lbs. Force (0-20 kN)
                                                                                00 lbs. (0.5 kN) gauge division

                                                               The tensile load is applied to the fixing mechanically;
                                                               hydraulics are used to register the load only. This
                                                               enhances the systems’ reliability as it is not prone to
                                                               hydraulic leaks. Also, mechanical loading provides
                                                               smoother operation, eliminating hydraulic backlash.

                                                               Super Hydraulic Pump
                                                               Anchor Test System
                                                               Light Duty:      0-26,000 lbs (0-123 kN)

                                                               Heavy Duty:      0-52,000 lbs (0-255 kN)

                                                               The Load application is achieved via a hydraulic pump
                                                               driving a 4:1 hydraulic multiplier; the applied load is
                                                               recorded directly on a gauge mounted on the hydraulic
                                                               pump assembly. This new an improved design allows
                                                               for practical test of higher kN values.

                                                               An integral movement indication is provided allowing
          Standard Anchor
                                                               “first movement” to be identified as well as total
          Test System                                          displacement before failure.




















                                                                                     Super Anchor Test
                                                                                     System with Load
                                                                                     Diffusion Bridge












        18 NDT JAMES INSTRUMENTS INC.                                                         www.ndtjames.com