Page 76 - FORE JAMES DETAYLI 2018
P. 76
The James IQM & M-Meter System
Technical Specifications
Specifications Model M-IQM-4010: K-Thermocouple
Module
Memory Size: >8000 Data Points
Memory Type: Non-Volatile
Battery Type: 1-9 V Battery
Battery Life: @20°C: 30 Days recording
every 30 Minutes
Interval Between
Readings: From 1 Min. to
24 hrs. in Minute
Increments
Recording Temperature
Range: –20 to 100°C
Operating Temperature
Range: 0°-70°C
Dimensions: 1.5 x 2.5 x 5 inches
(38mm x 63 x 127mm)
Weight: 10 oz (280 grams)
Model M-IQM-4011: 3 ft (1 m) “K”Thermocouple
(included with every
M-IQM-4010
System accuracy ±1°C
Model M-IQM-4040: Software to calculate
Computer display of maturity - time calculated
with the arrnenius equation. maturity & strength
Operating
System: Windows ME/XP
Processor: 166 MHz Pentium or faster
Sales Numbers RAM: 32 MB
Hard Disk Space: 8 MB
IQM System
Model M-IQM-4010: Single Channel Maturity
M-Meter
meter (IQM)
M-M-3056
Model M-IQM-4011: 3ft. “K” Thermocouple
System Accuracy ±2% of maturity number
sensor
M-Meter Max Maturity Number 15000
M-M-3056: 6 Channel Ruggedized
Power Source Rechargeable 6V Battery
Maturity Meter
M-M-3009: Sensor Battery Life - 20 days at +20˚C
continuous operation
Activation Energy Level 22000 to 56000 J/Mol. in
increments of 2000
Operating Temperature O˚C to 55˚C
Range
Instrument Case Size 8.5 x 7.75 x 7 inches
Instrument Weight 7 lbs.
M-M-3009 Sensor
10 K Ohm NTC Thermister with 10 ft. of 18 GA
3727 North Kedzie Avenue,
Chicago, Illinois 60618 STP-1 lamp cord
1-800-426-6500 (773) 463-6565 Temperature Range: -10˚C to 80˚C
FAX (773) 463-0009 Accuracy: ±0.2%
e-mail: info@ndtjames.com M-M-3010 Printer
http://www.ndtjames.com Type Impact Dot Matrix - 6 x 8
Power Source - Rechargeable Battery
76 NDT JAMES INSTRUMENTS INC. www.ndtjames.com