Page 52 - Demo
P. 52
» Monolithic construction provides a wall-to-wall or joint-to-joint seamless floor
Explosive environments: Munitions, air bags, pyrotechnics processing areas
For Color Swatches See Page 53
DETAILS
RECOMMENDED SURFACE: SURFACE FINISH:
DRY FILM THICKNESS: COVERAGE:
INSTALL TEMPERATURE: DRY TIME: FOOT
FULL
Concrete
Smooth
90 mils / coat
70 sq. ft. / kit
70–90°F (21–32°C)
24 hours 72 hours
APPLICATION
INSTALLATION DIFFICULTY: COMPANION PRODUCTS:
APPLICATION TOOLS:
Difficult
Penetrating Prime
& SealTM Primer, UltraPlexTM ESD Primer
Screed Rake, Spike Roller
ULTRAPLEXTM C SL PROFILE
UltraPlexTM C SL or SD SL
(One or two coats)
Primer ESD
Penetrating Prime & Seal Primer
51
COATINGS
4700 SYSTEM: ULTRAPLEXTM
4700 System
ULTRAPLEXTM C SL
Self-leveling seamless floor coating, designed to meet the electrically conductive and anti-spark requirements of a wide variety of industrial flooring needs.
» Designed for areas requiring low resistance (25,000 ohms to 1 megohm at 500 volts, based on NFPA 99 test method)
» Resistance to a variety of acids, alkalis, and solvents — Chemical resistance equal to 8200 System OverKote series
» Meets the requirements for spark resistant floor topping
» Provides a wear surface for protection where conductive tile just isn’t enough
» Nonporous and of extreme high density — Resists gritting and traffic soil, will not support bacterial growth, will not hold odors, will not dust and is easily mopped clean
VOC <160g/l RESISTANCE:
Chemical Abrasion Impact Mechanical
70 24
WELL SUITED FOR:
MILD MILDMODERATE MILDMODERATE MILDMODERATE
SQ. FT.
HOURS
SEVERE