                                                      Installation









































                                                                                          Dr. Blade Holder Screw

                                                                                                SAM81950005
                                                                                                   $0.54



                 Incorrect





                                                                       Maximize Blade Life

                                     Correct


         Minimize Pressure - Maximize Blade Life . . .

         Correct installation and Blade Orientation will Minimize the Blade-to-Anilox Pressure required to
         wipe the surface of the anilox cleanly!


         “A good way to tell if you’re using the correct amount of doctor blade pressure is to look at the roll once it’s inked. Before increasing pressure,
         the ANILOX ROLL will appear GLOSSY This is a sign that TOO MUCH INK IS REMAINING on the surface.
         Pressure should be increased gradually until a satin finish appears on the surface of the roll. A SATIN FINISH is a good indication that the
         CORRECT AMOUNT OF PRESSURE has been achieved and the doctor blade is effectively shearing the excess ink from the roll. If pressure is
         increased beyond this point, the doctor blade edge will bend and hydroplane. ”