Page 148 - BlueFastening-Systems_Brochure_07192017
P. 148

TriPress® – Reduces assembly time by up to 75 %

Fitting recommendations
for ductile light metals

                                                                             Core hole diameter recommen-
                                                                             dations for light metal alloys 1)

                                                                             Applicable to centre collar variant
                                                                             (TriPress®-MB) and the head variant
                                                                             (TriPress®-K)

Core hole recommendation for cast holes.            Tolerance range H11 for
             Max. draft angle a = 1 °                    bore diameter F

TriPress®  ØC                  Cast core hole       Drilled core hole        Minimum tube  Minimum distance
nom. Ø d   [mm]                Ø B [mm] at depth X  Ø F [mm]                 Ø H [mm]      From edge J [mm]
                                                    2.65                     5.60          1.40
2.8        2.90                2.63                 3.10                     6.60          1.60
                                                    3.50                     7.40          1.80
3.3        3.40                3.06                 4.40                     9.20          2.30
                                                    5.30                     10.80         2.70
3.7        3.80                3.48                 7.20                     14.80         3.70

4.6        4.80                4.40

5.4        5.60                5.26

7.4 7.60 7.18

Core hole depth K min = max press-in depthX + 1 mm

     Recommendation for determining the                   1) The above dimensions are merely guidelines, based principally on     AAUUMM ·· HHeellaa··AARRNN__22001177__00120 ·3 ·K PDoVg·o0,·5’0,-5’0 -1/0171/1©7by©AbRyNAORLNDOULDMFUOMRFMOTRECMHTENICKHGNImKbGHm&bCHo.&KCGo. KG
     TriPress® design                                     theoretical calculations. It is therefore important that you carry out       Technical changes reserve · Any reprinting - including extracts - requires permission.
                                                          the relevant laboratory trials using production parts in order to
     For high tensile stress and low torsion stress:      determine the precise parameters (clinching and press-out forces),
     TriPress® with locking flutes only, in hardened and  core hole diameters, torsion moments etc.)
     tempered version (strength class 10.9) or EH grade.
     Recommended press-in depth X:
     1.5-2.54 x Nominal Ø d

ARNOLD UMFORMTECHNIK           ARNOLD FASTENING                         ARNOLD TECHNIQUE   ARNOLD FASTENERS
GmbH & Co. KG                  SYSTEMS Inc.                             FRANCE S.A.        (SHENYANG) Co., Ltd.

Carl-Arnold-Straße 25          1873 Rochester Industrial Ct, Rochester  4, rue St Didier   No. 119-2 Jianshe Road
D-74670 Forchtenberg-Ernsbach  Hills, MI 48309-3336, USA                F-26140 Anneyron   CN-110122 Shenyang
T +49 7947 821-0               T +1248 997-2000                         T +33 475 313260   T +86 24887 90633
F +49 7947 821-111             F +1248 475-9470                         F +33 475 314440   F +86 24887 90999