"Oil-Less” Medical Air Medical Systems
8.0 Specifications (V-Series & G-Series)
Table 8-1 System Specifications for 1-20 HP Duplex with Mounted Tank
Duplex with Mounted Tank
HP Capacity 1 Receiver HP Capacity 1 Receiver
50 psig 100 psig (Gallons) 50 psig 100 psig (Gallons)
1 4.1 3.3 80 7½ 29.0 26.3 120
2 7.8 6.6 80 10 38.7 34.2 120
3 12.3 10.3 80 15 58.5 51.3 200
5 19.6 17.3 80 20 78.4 66.3 200
Table 8-2 System Specifications for 7.5-20 HP Base Mounted Modular and SPC Systems
Base Mounted Systems
DUPLEX TRIPLEX QUADRUPLEX
2
HP Capacity 1 Receiver 2 Capacity 1 Receiver 2 Capacity 1 Receiver
50 psig 100 psig (Gallons) 50 psig 100 psig (Gallons) 50 psig 100 psig (Gallons)
7½ 29.0 26.3 120 58.0 52.6 200 87.0 78.9 200
10 38.7 34.2 120 77.4 68.4 200 116.1 102.6 200
15 58.5 51.3 120 117.0 102.6 200 175.5 153.9 200
20 78.4 66.3 200 156.8 132.6 200 235.2 198.9 200
Notes: 1 All capacities are shown as NFPA system capacities (reserve compressor on standby) and
are shown in Inlet Cubic Feet per Minute (ICFM).
2 All receivers are supplied separately with base mounted modular systems.
Warning:
Verify compressor series type prior to servicing or ordering replacement parts or kits. The
model number of the compressor is located on the back of the compressor crankcase. Compare
the number to the chart below to determine compressor series type ("V" or "G").
HP V-Series Model No’s G-Series Model No’s
1 .75OU-8.5CH .75OU-9.5CGH
2 1.5OU-8.5CH 1.5OU-9.5CGH
3 2.2OU-8.5CH 2.2OU-9.5CGH
5 3.7OU-8.5CH 3.7OU-9.5CGH
7.5 5.5OU-8.5CH 5.5OU-9.5CGH
10 7.5OU-7CVH 7.5OU-8.5CG2H
15 11OU-7CVH 11OU-8.5CG2H
20 15OU-7CVH 15OU-7CVH
8-1