Page 185 - Med Plaza and Cancer Center
P. 185

"Oil-Less” Medical Air                                                              Medical Systems


               8.0 Specifications (V-Series & G-Series)


               Table 8-1 System Specifications for 1-20 HP Duplex with Mounted Tank
                 Duplex with Mounted Tank

                 HP          Capacity 1         Receiver     HP            Capacity 1           Receiver
                         50 psig    100 psig    (Gallons)            50 psig      100 psig     (Gallons)
                  1       4.1         3.3          80        7½        29.0         26.3          120
                  2       7.8         6.6          80        10        38.7         34.2          120
                  3       12.3        10.3         80        15        58.5         51.3          200
                  5       19.6        17.3         80        20        78.4         66.3          200

               Table 8-2 System Specifications for 7.5-20 HP Base Mounted Modular and SPC Systems
                 Base Mounted Systems

                                 DUPLEX                       TRIPLEX                     QUADRUPLEX
                                                                                                              2
                 HP        Capacity 1     Receiver 2     Capacity 1     Receiver 2     Capacity 1     Receiver
                       50 psig   100 psig  (Gallons)   50 psig   100 psig  (Gallons)   50 psig   100 psig  (Gallons)
                 7½     29.0      26.3       120       58.0     52.6       200       87.0     78.9       200
                  10    38.7      34.2       120       77.4     68.4       200      116.1     102.6      200
                  15    58.5      51.3       120      117.0     102.6      200      175.5     153.9      200
                  20    78.4      66.3       200      156.8     132.6      200      235.2     198.9      200

               Notes:   1   All capacities are shown as NFPA system capacities (reserve compressor on standby) and
                         are shown in Inlet Cubic Feet per Minute  (ICFM).
                        2  All receivers are supplied separately with base mounted modular systems.


                                                       Warning:
                  Verify compressor series type prior to servicing or ordering replacement parts or kits. The
                 model number of the compressor is located on the back of the compressor crankcase. Compare
                      the number to the chart below to determine compressor series type ("V" or "G").

                       HP                 V-Series Model No’s              G-Series Model No’s


                        1                    .75OU-8.5CH                      .75OU-9.5CGH
                        2                    1.5OU-8.5CH                      1.5OU-9.5CGH
                        3                    2.2OU-8.5CH                      2.2OU-9.5CGH
                        5                    3.7OU-8.5CH                      3.7OU-9.5CGH
                       7.5                   5.5OU-8.5CH                      5.5OU-9.5CGH
                        10                   7.5OU-7CVH                      7.5OU-8.5CG2H
                        15                   11OU-7CVH                        11OU-8.5CG2H
                        20                   15OU-7CVH                         15OU-7CVH






                                                             8-1