           B.2.2   Parameter List (continued)

                                                                                     Minimum
                                                                                      Setting     Initial   Factory
            Function Parameters              Name                 Setting Range     Increments    Value    Setting
                         261     Power failure stop selection   0, 1, 2                  1           0       2 +

                                 Subtracted frequency at
                         262     deceleration start              0 to 20Hz             0.01Hz       3Hz
                Power failure stop  263  Subtraction starting frequency    0 to 120Hz, 9999     0.1/0.01s     60Hz
                                                                                       0.01Hz
                                 Power-failure deceleration time
                         264
                                                                                                     5s
                                                                 0 to 3600/ 360s
                                 1
                                 Power-failure deceleration time
                         265
                                                               9999
                                 2                               0 to 3600/ 360s,     0.1/0.01s     9999
                                 Power failure deceleration time
                         266                                     0 to 400Hz            0.01Hz      60Hz
                                 switchover frequency
              ----       267     Terminal 4 input selection     0, 1, 2                  1           0       1 +
              ----       268     Monitor decimal digits selection   0, 1, 9999           1         9999
              ----       269     Parameter for manufacturer setting. Do not set.
                                 Rotation direction detection
              ----       299                                    0, 1, 9999               1         9999
                                 selection at restarting
                        300      BCD input bias
                         301     BCD input gain

                Digital input  302  BIN input bias             Parameter for digital input option (FR-A7AX)

                         303
                                 BIN input gain
                                 compensation enable/disable
                         304     Digital input and analog input
                                 selection
                         305     Read timing operation selection
                         306     Analog output signal selection

                         307     Setting for zero analog output
                                 Setting for maximum analog
                         308     output
                Analog output  309  Analog output signal voltage/  Extension analog output/digital output option
                                 current switchover
                                                               Parameter for (FR-A7AY)
                                 Analog meter voltage output
                         310
                                 selection
                                 Setting for zero analog meter
                         311
                                 voltage output
                                 Setting for maximum analog
                         312
                                 meter voltage output
                                                           + Indicates setting changed from initial value