"Oil-Less” Scroll Medical Air                                                       Medical Systems


               Appendix A - Desiccant Dryer


               A.4.1 Maintenance Schedule


                                    20 hp Triplex, 15 hp Quad (Type 2 Dryer) 155 cfm
                          Service Interval     Part number           Description          Quantity
                             Every year       (see section 5.2)        Pre-filter            2
                             Every year       (see section 5.2)       After-filter           2
                             Every year        MUF 01 008            Purge muffler           2
                            Every 5 years      DES 01 001              Desiccant           9 bags
                            Every 5 years      VAL 01 013            Check valve             4
                            Every 5 years      GKT 10 008            Tower o-ring            4
                            Every 5 years      GKT 10 007           Canister o-ring          4
                             As needed         VAL 11 003           Switching valve          2
                             As needed         GAG 01 032        Tower pressure gauge        2
                                          Purge valve (Refer to diagram for correct valve)
                            Every 5 years      VAL 04 020             Diaphragm              2
                            Every 5 years      VAL 04 031               Poppet               2

                                            20 hp Quad (Type 2 Dryer) 200 cfm
                          Service Interval     Part number           Description          Quantity
                             Every year       (see section 5.2)        Pre-filter            2
                             Every year       (see section 5.2)       After-filter           2
                             Every year        MUF 01 008            Purge muffler           2
                            Every 5 years      DES 01 001              Desiccant          11 bags
                            Every 5 years      VAL 01 013            Check valve             4
                            Every 5 years      GKT 10 008            Tower o-ring            4
                            Every 5 years      GKT 10 007           Canister o-ring          4
                             As needed         VAL 11 003           Switching valve          2
                             As needed         GAG 01 032        Tower pressure gauge        2
                                          Purge valve (Refer to diagram for correct valve)
                            Every 5 years      VAL 04 020             Diaphragm              2
                            Every 5 years      VAL 04 031               Poppet               2


























                                                            A-12