Glulam
Dimensional Information
Planted Root Option
Height (m) BD (mm) BH (m) TD (mm) WH (m) PD (mm) DH x DW (mm) Mass (kg) OTM (kNm) Shear (kN) Min. Concrete Dia. (mm)
4 140 1,4 100 2,6 800 500 x 100 54,0 11,28 3,11 1138
5 140 1,4 100 3,6 800 500 x 100 58,5 11,09 3,06 1092
6 140 1,4 100 4,6 1000 500 x 100 68,0 10,92 2,92 553
Flange Plated Option
Height BD BH TD WH DH x DW SL x T x BC Anchor Mass OTM Shear Concrete Foundation
(m) (mm) (m) (mm) (m) (mm) (mm) Bolts (kg) (kNm) (kN) Size (mm)
4 140 1,4 100 2,6 500 x 100 270 x 12 x 200 M14/16 x 300 45,0 11,28 3,11 500 sq x 900 h
5 140 1,4 100 3,6 500 x 100 270 x 12 x 200 M14/16 x 300 49,5 11,09 3,06 500 sq x 900 h
6 140 1,4 100 4,6 500 x 100 270 x 12 x 200 M14/16 x 300 55,5 10,92 2,92 500 sq x 900 h
Headload Capacity Information
Height (m) Mounting Arrangement Projection (m ) 2 Weight (kg) Extra Light Light Medium Heavy Extra Heavy
4 Post Top N/A 50 2,55 2,22 2,02 1,82 1,39
5 Post Top N/A 50 1,64 1,4 1,26 1,13 0,84
6 Post Top N/A 30 1,12 0,93 0,83 0,71 0,49
Dimensions and technical information given as an indication.
See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it