Page 47 - UK Standard Products Catalogue 2018_23.10.18
P. 47
Galvanised Steel
Dimensional Information
Planted Root Option: Supplied with bolt-on root
Height BD TD PD DH x DW Mass OTM Shear Min. Concrete Dia.
(m) (mm) (mm) (mm) (mm) (kg) (kNm) (kN) (mm)
4,5 130 60 800 400 x 75 44 4,62 1,37 460
5 138 60 800 400 x 75 50 5,51 1,50 543
6 151 60 1000 500 x 85 64 6,53 1,53 330
8 183 60 1200 500 x 90 98 11,07 2,01 321
9 202 60 1500 500 x 90 120 13,57 2,21 204
10 215 60 1500 500 x 90 139 16,72 2,48 248
11 238 60 1700 500 x 100 170,5 20,44 2,79 209
12 257 60 1700 500 x 105 191 23,66 3,04 240
Flange Plated Option
Height BD TD DH x DW SL x T x BC Anchor Mass OTM Shear (kN) Concrete Foundation
(m) (mm) (mm) (mm) (mm) Bolts (kg) (kNm) Size (mm)
4,5 130 60 400 x 75 271 x 4 x 200 M14/16 x 300 38,0 4,62 1,37 400 sq x 600 h
5 138 60 400 x 75 271 x 4 x 200 M14/16 x 300 43,0 5,51 1,50 400 sq x 700 h
6 151 60 500 x 85 412 x 6 x 300 M18/20 x 400 59,0 6,53 1,53 400 sq x 700 h
8 183 60 500 x 90 412 x 6 x 300 M18/20 x 400 87,5 11,07 2,01 500 sq x 900 h
9 202 60 500 x 90 412 x 6 x 300 M18/20 x 400 103,0 13,57 2,21 500 sq x 1000 h
10 215 60 500 x 90 412 x 6 x 300 M18/20 x 400 120,0 16,72 2,48 600 sq x 1000 h
11 238 60 500 x 100 400 x 16 x 300 M18/20 x 400 153,5 20,44 2,79 600 sq x 1100 h
12 257 60 500 x 105 400 x 16 x 300 M18/20 x 400 170,0 23,66 3,04 600 sq x 1200 h
Headload Capacity Information
Height (m) Mounting Height (m) Mounting Arrangement Projection (m) Weight (kg) Extra Light Light Medium Heavy Extra Heavy
4,5 4,0 Single Arm 0,47 15 1,06 0,92 0,85 0,77 0,60
5 4,37 Single Arm 0,66 15 1,17 1,01 0,92 0,84 0,65
6 5,27 Single Arm 0,45 15 1,06 0,92 0,84 0,76 0,58
8 7 Single Arm 0,97 15 0,96 0,82 0,75 0,66 0,51
9 8 Single Arm 1,31 15 0,92 0,79 0,71 0,64 0,49
10 9 Single Arm 1,47 15 0,99 0,85 0,77 0,69 0,52
11 10 Single Arm 1,75 15 1,01 0,86 0,78 0,70 0,52
12 11 Single Arm 1,95 15 1,00 0,85 0,77 0,69 0,51
Options:
Luminous spike O’light . Information on page 250
2
Dimensions and technical information given as an indication.
See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it
deems necessary to improve the products of the Standard Collection.