Page 83 - UK Standard Products Catalogue 2018_23.10.18
P. 83
Aluminium
Dimensional Information
Planted Root Option: Supplied with bolt-on root
Height (m) BD (mm) TD (mm) PD (mm) DH x DW (mm) Mass (kg) OTM (kNm) Shear (kN) Min. Concrete Dia. (mm)
4 200 76 800 450 x 120 25 6,24 1,66 630
5 200 76 800 450 x 120 30 6,17 1,50 607
6 200 76 1000 450 x 120 36 6,06 1,30 307
Flange Plated Option
Height BD TD DH x DW SL x T x BC Anchor Mass OTM Shear Concrete Foundation Size
(m) (mm) (mm) (mm) (mm) Bolts (kg) (kNm) (kN) (mm)
4 200 76 450 x 120 400 x 15 x 300 M18/20 x 400 24 6,24 1,66 400 sq x 700 h
5 200 76 450 x 120 400 x 15 x 300 M18/20 x 400 29 6,17 1,50 400 sq x 700 h
6 200 76 450 x 120 400 x 15 x 300 M18/20 x 400 34 6,06 1,30 400 sq x 700 h
Headload Capacity Information
Height (m) Mounting Arrangement Projection (m) Weight (kg) Extra Light Light Medium Heavy Extra Heavy
Post Top N/A 50 1,31 1,14 1,05 0,96 0,76
4
Post Top Side N/A 15 1,16 1,01 0,93 0,85 0,67
Post Top N/A 50 0,89 0,77 0,70 0,63 0,50
5
Post Top Side N/A 15 0,84 0,73 0,66 0,60 0,48
Post Top N/A 30 0,64 0,55 0,50 0,44 0,33
6
Post Top Side N/A 15 0,59 0,51 0,46 0,42 0,32
Dimensions and technical information given as an indication.
See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it
deems necessary to improve the products of the Standard Collection.