Zavation Spinal System




                 Spinal System Benefits and Features


                •  Standard and Cannulated versions
                •  25° (50° cone) variable head angulation
                •  Dual lead thread profile:
                       • Major dia: straight
                       • Minor dia: straight (series 10-<product ID>, 12-, and 13-) or tapered
                          (series 11- and 14-) option
                •  Screw will accept either 5.5mm or 6.0mm rod                   MIS Reduction screw
                •  MIS reduction screw with “break-off” tang available           with “break-off”
                •  Set screw
                       • Square thread to prevent cross threading
                       • Reverse angle thread prevents head splay
                •  Rod Connector
                       • 3° of freedom
                       • Snap on rod


                      Polyaxial Screws         Diameter (mm)           Length (mm)

                      Standard & Cannulated 4.5, 5.5                   25 to 65 (in 5mm increments)
                                               6.5, 7.5, 8.5           25 to 100 (in 5mm increments)

                      Rods (15cm radius)       Diameter (mm)           Length (mm)
                      Straight                 5.5 and 6.0             40-450 (Straight)
                      Pre-bent                                         35-120 (Pre-bent)

                      Rod (Cross Connector) Diameter (mm)              Sizes available to accommodate
                                                                       rod spacing

                                               •  5.5 (10-XX series)   From 32 to 100mm
                                               •  6.0 (11-XX series)













                                                                                                  Square thread with
                                                                                                  reverse angle


                    220 Lakeland Parkway  —  Flowood, MS 39232  —  601.919.1119  —  info@zavation.com

                                                  WWW.ZAVATION.COM

                  *The information contained in this document is Zavation Medical Products, LLC. Proprietary Information. It shall not be used, disclosed
                  to others, or reproduced without the expressed written consent of Zavation Medical Products, LLC. For full instructions for use, visit
                  http://zavation.com/general-information/                                               ZSP-4525.P1A
   1   2   3   4   5