Page 411 - 2018_IFC
P. 411

AEROSOLS



           age area shall either be self-closing or provided with auto-  5106.2.1  Maximum quantities in retail display areas.
           matic-closing devices activated by sprinkler water flow or  Aerosol products and aerosol cooking spray products in
           an approved fire detection system.                    retail display areas shall not exceed quantities needed for
                                                                 display and  normal merchandising  and shall not exceed
         5104.7 Storage in Group M occupancies. Storage of Level
         2 and 3 aerosol products and aerosol cooking spray products  the quantities in Table 5106.2.1.
         in occupancies in Group M shall comply with Table 5104.7.               TABLE 5106.2.1
         Retail display shall comply with Section 5106.           MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL
                                                                     PRODUCTS AND AEROSOL COOKING SPRAY
                            TABLE 5104.7                               PRODUCTS IN RETAIL DISPLAY AREAS
                 MAXIMUM QUANTITIES OF LEVEL 2 AND 3                                                  b
               AEROSOL PRODUCTS AND AEROSOL COOKING                    MAXIMUM NET WEIGHT PER FLOOR (pounds)
               SPRAY PRODUCTS IN RETAIL STORAGE AREAS                                    Protected in   Protected in
                                                                   Floor    Unprotected a  accordance with  accordance with
                  MAXIMUM NET WEIGHT PER FLOOR (pounds)                                Section 5106.2 a, c  Section 5106.3 c
                                       Segregated storage      Basement     Not Allowed     500         500
                      Nonsegregated
             Floor           a, b    Storage   Separated from
                        storage                                Ground          2,500      10,000       10,000
                                     cabinets b  retail area c
                                                               Upper           500         2,000     Not Allowed
         Basement     Not Permitted  Not Permitted  Not Permitted
                                                                                                 2
                                                              For SI: 1 pound = 0.454 kg, 1 square foot = 0.0929 m .
         Ground          2,500        5,000       Note d
                                                              a. The total quantity shall not exceed 1,000 pounds net weight in any one
         Upper            500         1,000       Note d        100-square-foot retail display area.
                                                              b. Per 25,000-square-foot retail display area.
                                           2
         For SI: 1 pound = 0.454 kg, 1 square foot = 0.0929 m .
                                                              c. Minimum Ordinary Hazard Group 2 wet-pipe automatic sprinkler system
         a. The total aggregate quantity on display and in storage shall not exceed the  throughout the retail sales occupancy.
           maximum retail display quantity indicated in Section 5106.3.
                                                                 5106.2.2 Aerosol cooking spray storage and fire protec-
         b. Storage quantities indicated are the maximum permitted in any 50,000-
           square-foot area.                                     tion. The storage and handling of aerosol cooking spray
         c. The storage area shall be separated from the retail area with a 1-hour fire-  products shall comply with this chapter and NFPA 30B.
           resistance-rated assembly.
                                                                 5106.2.3 Display of aerosol products. Level 2 and 3
         d. See Table 5104.3.2.
                                                                 aerosol products shall  not be stacked more than 6 feet
         5104.8 Storage of aerosol cooking spray products. Aerosol
                                                                 (1829 mm) high from the base of the aerosol product array
         cooking spray products shall be permitted to be stored in a  to the top of the aerosol product array unless the aerosol
         general purpose warehouse.
                                                                 products are placed on fixed shelving or otherwise secured
           5104.8.1 Mixed  storage. Where  aerosol cooking  spray  in an approved manner. Where storage or retail display is
           products are mixed with other higher-hazard aerosol prod-  on shelves, the height of such storage or retail display to
           ucts, the provided isolation, storage height restrictions and  the top of aerosol products shall not exceed 8 feet (2438
           protection shall be based  on  the highest-hazard aerosol  mm).
           product present.
                                                                 5106.2.4 Combustible cartons. Aerosol products located
           5104.8.2 Storage conditions. The storage and handling of  in retail display areas shall be removed from combustible
           aerosol cooking  spray products shall comply  with this  cartons.
           chapter and NFPA 30B.
                                                                   Exceptions:
                                                                     1. Display areas that use a portion of combustible
                           SECTION 5105                                 cartons that consist of only the bottom panel and
                        OUTSIDE STORAGE                                 not more than 2 inches (51 mm) of the side panel
                                                                        are allowed.
         5105.1 General. The outside storage of Level 2 and 3 aerosol
         products, including  storage in temporary storage trailers,             TABLE 5105.1
         shall be separated from exposures in accordance with Table  DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE
         5105.1.                                                       OF LEVEL 2 AND 3 AEROSOL PRODUCTS
                                                                                           MINIMUM DISTANCE FROM
                                                                        EXPOSURE                             a
                                                                                           AEROSOL STORAGE (feet)
                           SECTION 5106                       Buildings                             50
                         RETAIL DISPLAY
                                                              Exit discharge to a public way        50
         5106.1 General. This section shall apply to the retail display  Lot lines                  20
         of 500 pounds (227 kg) or more of Level 2 and 3 aerosol  Other outside storage             50
         products and aerosol cooking spray products.
                                                              Public alleys, public ways, public
         5106.2  Aerosol  display and normal merchandising  not  streets                            20
         exceeding 8 feet high. Aerosol display and normal merchan-
         dising not exceeding 8 feet (2438 mm) in height shall be in  For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
                                                              a. The minimum separation distance indicated is not required where exterior
         accordance with Sections 5106.2.1 through 5106.2.5.
                                                                walls having a 2-hour fire-resistance rating without penetrations separate
                                                                the  storage from the exposure.  The  walls shall extend not  less than 30
                                                                inches above and to the sides of Level 2 and 3 aerosol products.
         378                                                                        2018 INTERNATIONAL FIRE CODE ®