STRUCTURAL DESIGN



                   2. 60  percent  for  members  supporting  two  or  L  = L  R R 2              (Equation 16-26)
                                                                          1
                                                                    r
                                                                        o
                     more floors.                                  where: 12  L   20
                   3. R as determined by the following equation:              r
                                                                   For SI: L  = L R R
                                                                          r   o  1  2
                 R = 23.1(1+ D/L )          (Equation 16-25)       where: 0.58  L   0.96
                              o
                                                                                r
                                                                                                            2
                where:                                             L = Unreduced roof live load per square foot (m ) of
                                                                    o
                A = Area of floor supported by the member, square       horizontal  projection  supported  by  the  member
                           2
                     feet (m ).                                         (see Table 1607.1).
                                                                                                            2
                                                                   L = Reduced  roof  live  load  per  square  foot  (m )  of
                D = Dead  load  per  square  foot  (m )  of  area   r   horizontal projection supported by the member.
                                                 2
                     supported.
                                                                   The reduction factors R  and R  shall be determined as
                L = Unreduced  live  load  per  square  foot  (m )  of                1     2
                                                      2
                 o                                                 follows:
                     area supported.
                                                                                                   2
                                                                   R  = 1 for A   200 square feet (18.58 m )
                R = Reduction in percent.                           1        t
                                                                                                 (Equation 16-27)
         1607.12 Distribution of floor loads.  Where  uniform  floor  R  = 1.2 - 0.001A  for 200 square feet
         live loads are involved in the design of structural members  1          t
         arranged  so  as  to  create  continuity,  the  minimum  applied  < A  < 600 square feet  (Equation 16-28)
                                                                        t
         loads shall be the full dead loads on all spans in combination  For  SI:  1.2  - 0.011A   for  18.58  square meters  < A  <
                                                                                    t
                                                                                                             t
         with  the  floor  live  loads  on  spans  selected  to  produce  the  55.74 square meters
         greatest  load effect  at  each  location  under  consideration.  R  = 0.6 for A   600 square feet (55.74 m )
                                                                                                    2
         Floor live  loads are permitted to be reduced  in  accordance  1     t
         with Section 1607.11.                                                                   (Equation 16-29)
                                                                   where:
         1607.13 Roof loads.  The  structural  supports  of  roofs  and
         marquees shall be designed to resist wind and, where applica-  A = Tributary area (span length multiplied by effective
                                                                    t
                                                                                              2
         ble, snow and earthquake loads, in addition to the dead load   width)  in  square  feet  (m )  supported  by  the
         of construction and the appropriate live loads as prescribed in  member, and
         this section, or as set forth in Table 1607.1. The live loads  R  = 1 for F  4         (Equation 16-30)
                                                                    2
         acting on a sloping surface shall be assumed to act vertically  R  = 1.2 - 0.05 F for 4 < F < 12
         on the horizontal projection of that surface.              2                            (Equation 16-31)
                                                                   R  = 0.6 for F  12           (Equation 16-32)
           1607.13.1  Distribution of roof loads.  Where  uniform   2
           roof live loads are reduced to less than 20 psf (0.96 kN/m )  where:
                                                         2
           in accordance with Section 1607.13.2.1 and are applied to  F = For a sloped roof, the number of inches of rise
           the design of structural members arranged so as to create    per  foot  (for  SI:  F  =  0.12  ×  slope,  with  slope
           continuity, the reduced roof live load shall be applied to   expressed  as  a  percentage),  or  for  an  arch  or
           adjacent spans or to alternate spans, whichever produces     dome, the rise-to-span ratio multiplied by 32.
           the  most  unfavorable load effect.  See  Section 1607.13.2  1607.13.3 Occupiable roofs. Areas of roofs that are occu-
           for reductions in minimum roof live loads and Section 7.5  piable, such as vegetative roofs, roof gardens or for assem-
           of ASCE 7 for partial snow loading.                   bly or other similar purposes, and marquees are permitted
           1607.13.2 General.  The minimum  uniformly distributed  to have their uniformly distributed live loads reduced in
           live loads of roofs and marquees, L , in Table 1607.1 are  accordance with Section 1607.11.
                                        o
           permitted  to  be  reduced  in  accordance  with  Section  1607.13.3.1 Vegetative and landscaped  roofs.  The
           1607.13.2.1.                                            weight of all landscaping materials shall be considered
              1607.13.2.1 Ordinary roofs, awnings and canopies.    as dead load and shall be computed on the basis of satu-
              Ordinary  flat,  pitched  and  curved  roofs,  and  awnings  ration of the soil as determined in accordance with Sec-
              and  canopies  other  than  of  fabric  construction  sup-  tion 3.1.4 of ASCE 7. The uniform design live load in
              ported  by  a  skeleton  structure,  are  permitted  to  be  unoccupied landscaped areas on roofs shall be 20 psf
                                                                             2
              designed for a reduced uniformly distributed roof live  (0.958 kN/m ). The uniform design live load for occu-
              load, L  as specified in the following equations or other  pied landscaped areas on roofs shall be determined in
                   r,
              controlling combinations of loads as specified in Sec-  accordance with Table 1607.1.
              tion 1605, whichever produces the greater load effect.  1607.13.4 Awnings and canopies. Awnings and canopies
                 In  structures  such  as  greenhouses,  where  special  shall  be  designed  for  uniform  live  loads  as  required  in
              scaffolding is used as a work surface for workers and  Table 1607.1 as well as for snow loads and wind loads as
              materials during maintenance and repair operations, a  specified in Sections 1608 and 1609.
              lower roof load than specified in the following equa-  1607.13.5 Photovoltaic panel  systems.  Roof  structures
              tions shall not be used unless approved by the building  that provide support for photovoltaic panel systems shall
              official. Such structures shall be designed for a mini-  be  designed  in  accordance  with  Sections  1607.13.5.1
                                               2
              mum roof live load of 12 psf (0.58 kN/m ).         through 1607.13.5.4, as applicable.
         372                                                                    2018 INTERNATIONAL BUILDING CODE  ®