SOILS AND FOUNDATIONS



                  connected  to  the  pile  cap  by  embedding  the  element  the full axial, bending and shear nominal strength
                  reinforcement  or  field-placed  dowels  anchored  in  the  of the element.
                  element into the pile cap for a distance equal to their  Where  the  vertical  lateral-force-resisting  elements
                  development  length  in  accordance  with  ACI  318.  It  are columns, the pile cap flexural strengths shall exceed
                  shall be permitted to connect precast prestressed piles  the column flexural strength. The connection between
                  to the pile cap by developing the element prestressing  batter piles and pile caps shall be designed to resist the
                  strands into the pile cap provided that the connection is  nominal strength of the pile acting as a short column.
                  ductile. For deformed bars, the development length is  Batter  piles  and  their  connection  shall  be  designed  to
                  the full development length for compression, or tension  resist forces and moments that result from the applica-
                  in the case of uplift, without reduction for excess rein-  tion of seismic load effects including overstrength factor
                  forcement in accordance with Section 25.4.10 of ACI  in accordance with Section 2.3.6 or 2.4.5 of ASCE 7.
                  318. Alternative measures for laterally confining con-
                  crete  and  maintaining  toughness  and  ductile-like  1810.3.12 Grade beams. For structures assigned to Seis-
                                                                     mic Design Category D, E or F, grade beams shall comply
                  behavior at  the  top  of the  element  shall be permitted  with  the  provisions  in  Section  18.13.3  of  ACI  318  for
                  provided that the design is such that any hinging occurs  grade beams, except where they are designed to resist the
                  in the confined region.                            seismic load effects including overstrength factor in accor-
                    The minimum transverse steel ratio for confinement  dance with Section 2.3.6 or 2.4.5 of ASCE 7.
                  shall be not less than one-half of that required for col-
                  umns.                                              1810.3.13 Seismic ties. For structures assigned to Seismic
                                                                     Design Category C, D, E or F, individual deep foundations
                    For  resistance  to  uplift  forces,  anchorage  of  steel  shall be interconnected by ties. Unless it can be demon-
                  pipes, tubes or H-piles to the pile cap shall be made by  strated that equivalent restraint is provided by reinforced
                  means other than concrete bond to the bare steel sec-  concrete beams within slabs on grade or reinforced con-
                  tion.  Concrete-filled  steel  pipes  or  tubes  shall  have  crete  slabs  on  grade or confinement by  competent  rock,
                  reinforcement of not less than 0.01 times the cross-sec-  hard cohesive soils or very dense granular soils, ties shall
                  tional area of the concrete fill developed into the cap  be capable of carrying, in tension or compression, a force
                  and extending into the fill a length equal to two times  equal to the lesser of the product of the larger pile cap or
                  the  required  cap  embedment,  but  not  less  than  the  column design gravity load times the seismic coefficient,
                  development length in tension of the reinforcement.  S , divided by 10, and 25 percent of the smaller pile or
                                                                      DS
                  1810.3.11.2 Seismic Design Categories D through F.  column design gravity load.
                  For structures assigned to Seismic Design Category D,  Exception: In Group R-3 and U occupancies of light-
                  E  or  F,  deep  foundation  element  resistance  to  uplift  frame construction, deep foundation elements support-
                  forces  or  rotational  restraint  shall  be  provided  by  ing foundation walls, isolated interior posts detailed so
                  anchorage into the  pile cap, designed considering the  the  element  is  not  subject  to  lateral  loads  or  exterior
                  combined effect of axial forces due to uplift and bend-  decks  and  patios  are  not  subject  to  interconnection
                  ing moments due to fixity to the pile cap. Anchorage  where the soils are of adequate stiffness, subject to the
                  shall develop not less than 25 percent of the strength of  approval of the building official.
                  the  element  in  tension.  Anchorage  into  the  pile  cap
                  shall comply with the following:                1810.4 Installation. Deep  foundations  shall  be  installed  in
                                                                  accordance with Section 1810.4. Where a single deep founda-
                    1. In the case of uplift, the anchorage shall be capa-  tion  element  comprises  two  or  more  sections  of  different
                       ble of developing the least of the following:   materials  or  different  types  spliced  together,  each  section
                         1.1. The nominal tensile strength of the longi-  shall satisfy the applicable conditions of installation.
                             tudinal  reinforcement  in  a  concrete  ele-  1810.4.1 Structural integrity. Deep foundation elements
                             ment.                                   shall be installed in such a manner and sequence as to pre-
                         1.2. The  nominal  tensile  strength  of  a  steel  vent distortion or damage that would adversely affect the
                             element.                                structural integrity of adjacent structures or of foundation
                         1.3. The  frictional  force  developed  between  elements being installed or already in place and as to avoid
                             the element and the soil multiplied by 1.3.  compacting  the surrounding  soil  to the  extent that  other
                         Exception: The anchorage is permitted to be  foundation elements cannot be installed properly.
                         designed  to  resist  the  axial  tension  force  1810.4.1.1 Compressive  strength of precast con-
                         resulting from the seismic load effects includ-  crete piles. A precast concrete pile shall not be driven
                         ing  overstrength  factor  in  accordance  with  before  the  concrete  has  attained  a  compressive
                         Section 2.3.6 or 2.4.5 of ASCE 7.             strength  of  not  less  than  75  percent  of  the  specified
                    2. In the case of rotational restraint, the anchorage  compressive  strength  (f   ),  but  not  less  than  the
                                                                                             c
                       shall  be  designed  to  resist  the  axial  and  shear  strength sufficient  to  withstand handling  and  driving
                       forces, and moments resulting from the seismic  forces.
                       load  effects  including  overstrength  factor  in  1810.4.1.2 Casing.  Where cast-in-place  deep founda-
                       accordance with Section 2.3.6 or 2.4.5 of ASCE 7  tion  elements  are  formed  through  unstable  soils  and
                       or the anchorage shall be capable of developing  concrete is placed in an open-drilled hole, a casing shall