PLUMBING SYSTEMS
[P] TABLE 2902.1—(continued)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
a
(See Sections 2902.1.1 and 2902.2)
WATER CLOSETS DRINKING
(URINALS SEE SECTION FOUNTAINS
424.2 OF THE LAVATORIES (SEE SECTION
No. CLASSIFICATION DESCRIPTION INTERNATIONAL BATHTUBS/ 410 OF THE OTHER
SHOWERS
PLUMBING CODE) INTERNATIONAL
PLUMBING
Male Female Male Female CODE)
Auditoriums without per-
manent seating, art galler-
ies, exhibition halls, 1 per 125 1 per 65 1 per 200 — 1 per 500 1 service
museums, lecture halls, sink
libraries, arcades and
d
gymnasiums
Passenger terminals and 1 per 500 1 per 500 1 per 750 — 1 per 1,000 1 service
transportation facilities d sink
Places of worship and 1 per 150 1 per 75 1 per 200 — 1 per 1,000 1 service
d
other religious services sink
1 per 75 for 1 per 40 for
1 Assembly Coliseums, arenas, skat- the first the first
ing rinks, pools and tennis 1,500 and 1 1,520 and 1 1 per 1 per — 1 per 1,000 1 service
per 120 for per 60 for
courts for indoor sporting the remain- the remain- 200 150 sink
events and activities
der exceed- der exceed-
ing 1,500 ing 1,520
1 per 75 for 1 per 40 for
Stadiums, amusement the first the first
parks, bleachers and 1,500 and 1 1,520 and 1 1 per 1 per 1 service
grandstands for outdoor per 120 for per 60 for 200 150 — 1 per 1,000 sink
sporting events and the remain- the remain-
activities f der exceed- der exceed-
ing 1,500 ing 1,520
Buildings for the transac-
tion of business, profes-
sional services, other 1 per 25 for the first 50 1 per 40 for the
services involving mer- first 80 and 1 per 1 service
2 B u s i n e s s and 1 per 50 for the — 1 per 100
chandise, office buildings, remainder exceeding 50 80 for the remain- sink e
banks, light industrial, der exceeding 80
ambulatory care and simi-
lar uses
Educational 1 service
3 Educational 1 per 50 1 per 50 — 1 per 100
facilities sink
Structures in which occu-
pants are engaged in work
Factory and 1 service
4 fabricating, assembly or 1 per 100 1 per 100 — 1 per 400
industrial sink
processing of products or
materials
1 service
Custodial care facilities 1 per 10 1 per 10 1 per 8 1 per 100
sink
Medical care recipients in 1 service
hospitals and nursing 1 per room c 1 per room c 1 per 15 1 per 100 sink
homes b
5 Institutional Employees in hospitals 1 per 25 1 per 35 — 1 per 100 —
and nursing homes b
Visitors in hospitals and 1 per 75 1 per 100 — 1 per 500 —
nursing homes
1 service
Prisons 1 per cell 1 per cell 1 per 15 1 per 100
b
sink
(continued)
588 2018 INTERNATIONAL BUILDING CODE ®
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.