Page 131 - ICC IEBC 2018
P. 131

APPENDIX A


                        MINIMUM FOUNDATION DIMENSIONS                     MINIMUM FOUNDATION REINFORCING
                                                                                     VERTICAL REINFORCING
          NUMBER OF     W          F         D a, b, c   T           H
           STORIES                                                           Single-pour wall and   Footing placed separate
                                                                                  footing          from wall
                                                                               #4 @ 48 inches    #4 @ 32 inches
             1       12 inches   6 inches  12 inches   6 inches  ≤ 24 inches
                                                                                 on center         on center
                                                                               #4 @ 48 inches    #4 @ 32 inches
             2       15 inches   7 inches  18 inches   8 inches  ≥ 36 inches
                                                                                 on center         on center
                                                                               #4 @ 48 inches    #4 @ 18 inches
             3       18 inches   8 inches  24 inches  10 inches  ≥ 36 inches
                                                                                 on center         on center
         For SI: 1 inch = 25.4 mm.
         a.  Where frost conditions occur, the minimum depth shall extend below the frost line.
         b.  The ground surface along the interior side of the foundation may be excavated to the elevation of the top of the footing.
         c. Where the soil is designated as expansive, the foundation depth and reinforcement shall be approved by the code official.






















                                                                      NEW ANCHORS SPACED AS
                                                                      REQUIRED BY TABLE A304.3.1.
                                                                      SEE FIGURE A304.3.1(1) FOR PLATE
                                                                      WASHER REQUIREMENTS
























         For SI:  1 inch = 25.4 mm, 1 foot = 304.8 mm.


                                                   [BS] FIGURE A304.2.3(1)
                                       NEW REINFORCED CONCRETE FOUNDATION SYSTEM







         112                                                            2018 INTERNATIONAL EXISTING BUILDING CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.