Page 138 - ICC IEBC 2018
P. 138
APPENDIX A
EXISTING CRIPPLE STUDS
SEE ALTERNATIVES BELOW FOR VERTICAL
PANEL JOINTS
8d NAILS AT 12 IN. ON CENTER AT INTERMEDIATE
STUDS. MIN 2 NAILS EACH STUD.
2x BLOCKING FLAT ABOVE VENT OPENING.
CONNECT TO STUDS WITH
SHEET METAL CONNECTORS.
2-IN.- TO 3-IN.-DIAMETER VENTILATION
HOLES. SEE SECTION A304.4.3.
1IN.
0.75H MIN CLEAR 8d NAILS AT 4 IN. ON CENTER
ON ALL EDGES OF EACH
H INDIVIDUAL PIECE
1IN.
CLEAR
GROUND LEVEL
EXISTING VENT
SILL BOLT
EXISTING FOUNDATION WALL
EXISTING STUD
1
2 / IN. MIN
2 8
NEW 2x CRIPPLE STUD NAILED TO
EXISTING STUD WITH 16d COMMON
NAILS AT 6 IN. ON CENTER AT WOOD 1 2 / IN. MIN
STRUCTURAL PANEL JOINT. 1 2 / IN. MIN
3 NAILS MIN.
3
3 / IN. MIN
/ IN. MIN 8 3
8
3 / IN. MIN
8
/ IN. MIN
8
1 1 8 / IN. MIN
8 / IN. MIN
VERTICAL SPLICE AT DOUBLE STUD VERTICAL SPLICE AT SINGLE STUD
For SI: 1 inch = 25.4 mm.
[BS] FIGURE A304.4.1(3)
PARTIAL CRIPPLE STUD WALL ELEVATION
2018 INTERNATIONAL EXISTING BUILDING CODE ® 119
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.