Page 216 - ICC IEBC 2018
P. 216

RESOURCE A



                                                           FIGURE 1.1.6
                                                         MASONRY WALLS
                                                     12″ TO LESS THAN 14″ THICK
              NUMBER OF
              ASSEMBLIES                                                        The number in each box is
                                                                                keyed to the last number in the
                                        81         84                           Item Code column in the Table.
                10                                                              For example:
                                        80         83
                                                                                       W-12-M-42
                                        76         82                   42

                                        64   87    78                   39
                                        59   61    77                   37

                                50      58   47    63   85              34
                5
                             46 48  60 62 57  31   49   79              23         73
                             30 44  53 55 56  27   45   75               9         70

                    51       26 20  22 52 54  21   41   72               7         66         74

                    33       18 14  16 17 29  8    36   68               4    24   43   35    38   67
                    32    28 12 11  13 15 19  3    25   65   86          2    10    1    5     6   40    59   71
                0
                   0    1    2     3    4     5    6     7    8    9    10   11    12   13    14   15    16   17
                                                   FIRE RESISTANCE RATING (HOURS)
                                                            TABLE 1.1.6
                                                         MASONRY WALLS
                                                     12″ TO LESS THAN 14″ THICK
                                                                PERFORMANCE       REFERENCE NUMBER
                                                                                                              REC.
              ITEM CODE  THICKNESS    CONSTRUCTION DETAILS                     PRE-BMS-         POST-  NOTES
                                                                LOAD    TIME            BMS-92                HOURS
                                                                                 92             BMS-92
                                Core: solid clay or shale brick;
             W-12-M-1     12″                                    N/A   12 hrs.            1              1     12
                                No facings.
                                Core: solid clay or shale brick;
             W-12-M-2     12″                                  160 psi  10 hrs.           1             1, 44  10
                                No facings.
                                Core: hollow rolok of clay or shale;
             W-12-M-3     12″                                  160 psi  5 hrs.            1             1, 44   5
                                No facings.
             W-12-M-4     12″   Core: hollow rolok bak of clay or shale;   160 psi  10 hrs.      1      1, 44  10
                                No facings.
             W-12-M-5     12″   Core: concrete brick; No facings.   160 psi  13 hrs.      1             1, 44  13
             W-12-M-6     12″   Core: sand-lime brick; No facings.   N/A  14 hrs.         1              1     14
             W-12-M-7     12″   Core: sand-lime brick; No facings.   160 psi  10 hrs.      1            1, 44  10
                                Cored clay or shale brick; Units in wall
             W-12-M-8     12″   thickness: 1; Cells in wall thickness: 2;   120 psi  5 hrs.      1      1, 45   5
                                Minimum % solids: 70; No facings.
                                Cored clay or shale brick; Units in wall
             W-12-M-9     12″   thickness: 3; Cells in wall thickness: 3;   160 psi  10 hrs.      1      1, 44  10
                                Minimum % solids: 87; No facings.
                                Cored clay or shale brick; Units in wall
             W-12-M-10    12″   thickness: 3; Cells in wall thickness: 3;   N/A  11 hrs.      1          1     11
                                Minimum % solids: 87; No facings.
                                                            (continued)



             2018 INTERNATIONAL EXISTING BUILDING CODE ®                                                         197
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   211   212   213   214   215   216   217   218   219   220   221