RESOURCE A



                                                       TABLE 1.2.1—continued
                                                        METAL FRAME WALLS
                                                      0″ TO LESS THAN 4″ THICK
                                                                 PERFORMANCE      REFERENCE NUMBER
                                                                                                              REC.
              ITEM CODE THICKNESS      CONSTRUCTION DETAILS                                  POST-BMS-  NOTES
                                                                 LOAD   TIME  PRE-BMS-92 BMS-92              HOURS
                                                                                                92
                                Solid  wall: steel  channel per Note 1;  2″
                                                                                                                3
             W-2-Me-5     2″    thickness of neat gypsum plaster on metal  N/A  1 hr.    1                     1 /
                                                                       45 min.                                   4
                                lath.
                                Solid  wall: steel  channel per Note 1;  2″
                                                                        1 hr.
                                            1
                                                 1
                                                                                                                1
             W-2-Me-6     2″    thickness of 1:1 / ; 1:1 / gypsum plaster on   N/A  30 min.  1                 1 / 2
                                                  2
                                             2
                                metal lath.
                                Solid  wall: steel  channel per Note 2;  2″
             W-2-Me-7     2″    thickness of 1:1; 1:1 gypsum  plaster  on   N/A  1 hr.      1                  1
                                metal lath.
                                Solid  wall: steel  channel per Note 1;  2″
             W-2-Me-8     2″    thickness of 1:2; 1:2 gypsum  plaster  on   N/A 45 min.      1                 3 / 4
                                metal lath.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               4
                          1
             W-2-Me-9    2 / ″  thickness  of 1:2; 1:3 portland cement on   N/A 30 min.      1                 1 / 2
                           4
                                metal lath.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               4
                          1
             W-2-Me-10   2 / ″  thickness of neat gypsum plaster on metal  N/A  2 hrs.      1                  2
                           4
                                lath.
                                Solid wall: steel channel per Note 2;
                                                                        1 hr.
                          1
                                 1
                                               1
                                                   1
                                                                                                                3
             W-2-Me-11   2 / ″  2 / ″thickness of 1: / ; 1: / gypsum plaster   N/A  45 min.  1                 1 / 4
                           4
                                  4
                                                    2
                                                2
                                on metal lath.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               4
                                                                        1 hr.
                                                                                                                1
                          1
             W-2-Me-12   2 / ″  thickness of 1:1; 1:1 gypsum  plaster  on   N/A  15 min.  1                    1 / 4
                           4
                                metal lath.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               4
                          1
             W-2-Me-13   2 / ″  thickness of 1:2; 1:2 gypsum  plaster  on   N/A  1 hr.      1                  1
                           4
                                metal lath.
                                Solid wall: steel channel per Note 1; 2 / ″
                                                              1
                                                               2
                          1
             W-2-Me-14   2 / ″  thickness of 4.5:1:7;  4.5:1:7  portland   N/A  1 hr.      1                   1
                           2    cement, sawdust and sand sprayed on wire
                                mesh; see Note 3.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               2
                          1
             W-2-Me-15   2 / ″  thickness of 1:4;  1:4  portland cement  N/A 20 min.      1                    1 / 3
                           2
                                sprayed on wire mesh; see Note 3.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               2
                          1
             W-2-Me-16   2 / ″  thickness  of 1:2; 1:3 portland cement on   N/A 30 min.      1                 1 / 2
                           2
                                metal lath.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               2
                                                                       2 hrs.
                          1
                                                                                                                1
             W-2-Me-17   2 / ″  thickness of neat gypsum plaster on metal  N/A  30 min.  1                     2 / 2
                           2
                                lath.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               2
                                           1
                                                1
                          1
             W-2-Me-18   2 / ″  thickness of  1: / ; 1: / gypsum plaster  on   N/A  2 hrs.      1              2
                                                 2
                                            2
                           2
                                metal lath.
                                Solid wall: steel channel per Note 2; 2 / ″
                                                              1
                                                               2
                                                                        1 hr.
                          1
                                                                                                                1
             W-2-Me-19   2 / ″  thickness of 1:1; 1:1 gypsum  plaster  on   N/A  30 min.  1                    1 / 2
                           2
                                metal lath.
                                                            (continued)
             2018 INTERNATIONAL EXISTING BUILDING CODE ®                                                         207
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   221   222   223   224   225   226   227   228   229   230   231