P. 258

RESOURCE A



                                                            TABLE 2.2
                                                    ROUND CAST IRON COLUMNS
                 ITEM    MINIMUM                                   PERFORMANCE     REFERENCE NUMBER            REC.
                 CODE    DIMENSION       CONSTRUCTION DETAILS      LOAD  TIME  PRE-BMS-92 BMS-92 POST-BMS-92  NOTES  HOURS
                                 Column: 0.6″ minimum metal  thickness;
              C-7-CI-1    7″ O.D.                                   —   30 min.           1                    1 /
                                 unprotected.                                                                    2
                                 Column: 0.6″ minimum metal thickness
              C-7-CI-2    7″ O.D.                                   —   45 min.           1                    3 /
                                 concrete filled, outside unprotected.                                           4
                                 Column: 0.6″ minimum metal thickness;
                                           1
              C-11-CI-3  11″ O.D. Protection: 1 / ″ portland cement plaster on   —  3  hrs.  1                  3
                                            2
                                                  1
                                 high ribbed metal lath,  / ″ broken air space.
                                                   2
                                 Column: 0.6″ minimum metal  thickness;
                                                                         2 hrs.
                                                                                                                1
              C-11-CI-4  11″ O.D. Protection: 2″ concrete other than siliceous   —        1                    2 /
                                                                        30 min.                                  2
                                 aggregate.
                                 Column: 7″ O.D. 0.6″ minimum metal thick-
                                 ness; Protection: 2″ porous hollow tile,  / ″
                                                               3
              C-12-CI-5  12.5″ O.D.                             4   —    3  hrs.          1                     3
                                 mortar between tile and column, outside
                                 wire ties.
                                              3
                                 Column: 7″ I.D.,  / ″ minimum metal thick-
              C-7-CI-6   7.6″ O.D.             10                   —   30 min.           1                    1 /
                                 ness, concrete filled unprotected.                                              2
                                              3
                                 Column: 8″ I.D.,  / ″ minimum metal thick-
                                               10
                                 ness; concrete filled reinforced with four
              C-8-CI-7   8.6″ O.D.                                  —    1  hr.           1                     1
                                 3 / ″  ×  / ″ angles, in fill; unprotected
                                       3
                                  1
                                   2    8
                                 outside.
             For SI: 1 inch = 25.4 mm.






































             2018 INTERNATIONAL EXISTING BUILDING CODE ®                                                         239
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.