Page 270 - ICC IEBC 2018
P. 270

RESOURCE A



                                                           FIGURE 2.5.1.6
                                              STEEL COLUMNS—CONCRETE ENCASEMENTS
                                               MINIMUM DIMENSION 14″ TO LESS THAN 16″
               NUMBER OF
              ASSEMBLIES

                10





                                                                            The number in each box is
                                                                            keyed to the last number in the
                                                                            Item Code column in the Table.

                                                                            For example:
                                                                                   C-15-SC-12
                 5








                                               14      9      13             12

                                        10  2   1      6       8      5       7      4              11      3
                 0
                    0      1       2      3       4      5       6      7       8      9      10      11     12
                                                  FIRE RESISTANCE RATING (HOURS)


                                                           TABLE 2.5.1.6
                                              STEEL COLUMNS—CONCRETE ENCASEMENTS
                                               MINIMUM DIMENSION 14″ TO LESS THAN 16″
                ITEM   MINIMUM                                    PERFORMANCE      REFERENCE NUMBER            REC.
                CODE   DIMENSION       CONSTRUCTION DETAILS        LOAD  TIME  PRE-BMS-92 BMS-92 POST-BMS-92  NOTES  HOURS
                               24″ × 16″ concrete encased steel column; 8″ ×
             C-14-SC-1   14″   6″ × 35 lbs. “H” column; Protection: aggregate   90 tons  3 hrs.   7       1     3
                               concrete (4240 psi); 4″ mesh - 16 SWG rein-  40 min.
                               forcing 1″ below column surface.
                               14″ × 18″ concrete encased steel column; 12″
                               × 8″ ×  65 lbs. “H” beam; Protection:  gravel   177  3 hrs.
             C-14-SC-2   14″   aggregate concrete (4000 psi) with 4″ - 16                         7       1     3
                                                                   tons  20 min.
                               SWG wire mesh reinforcement 1″ below col-
                               umn surface.
             C-14-SC-3   14″   10″ × 10″ steel column; 4″ outside protection;   —  12 hrs.      1         2     12
                               Group I.
             C-14-SC-4   14″   Description as per C-14-SC-3; Group II.   —  9 hrs.        1               2     9
                               24″ × 16″ concrete encased steel column; 8″ ×
             C-14-SC-1   14″   6″ × 35 lbs. “H” column; Protection: aggregate   90 tons  3 hrs.   7       1     3
                               concrete (4240 psi); 4″ mesh - 16 SWG rein-  40 min.
                               forcing 1″ below column surface.
                                                            (continued)






             2018 INTERNATIONAL EXISTING BUILDING CODE ®                                                         251
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.