Page 303 - ICC IEBC 2018
P. 303

RESOURCE A



                                                    TABLE 5.1—continued
                                           RESISTANCE OF DOORS TO FIRE EXPOSURE
                                                           PERFORMANCE          REFERENCE NUMBER
                        DOOR                                                                               REC.
          ITEM CODE                CONSTRUCTION DETAILS  EFFECTIVE                                   NOTES
                   MINIMUM THICKNESS                           EDGE FLAMING PRE- BMS-92 BMS-92 POST- BMS-92  (MIN.)
                                                        BARRIER
                                  As D-1, except  surface
          D-5            3 / ″    protected with  glass fiber   16 min.  N/A                   90    1, 3, 4,   15
                          8       reinforced  intumescent                                              7
                                  fire retardant coating.
                                  Door detail:  As D-4,
                                             1
                                  except with  / ″ cement
                                              8
                         5
          D-6           1 / ″     asbestos board facings   17 min.  10 min.                    90    1, 3, 4  15
                          8       with aluminum foil; door        15 sec.
                                  edges protected by sheet
                                  metal.
                                               1
                                  Door detail with  / ″ hard-
                                                8
                                  board cover each  side  as
                         5
          D-7           1 / ″     facings; glass fiber rein-  20 min.  N/A                     90    1, 3, 4,   20
                          8
                                                                                                       7
                                  forced intumescent  coat-
                                  ing applied.
                                  Door detail same as D-4;        24 min.                            1, 3, 4,
                         5
          D-8           1 / ″     paint was glass reinforced   26 min.  45 sec.                90     6, 7  25
                          8
                                  epoxy intumescent.
                                  Door detail  same as D-4        3 min.
                                              1
                         5
          D-9           1 / ″     with facings of  / ″ cement   29 min.  15 sec.               90     1, 2   5
                                               8
                          8
                                  asbestos board.
                         5
          D-10          1 / ″     As per D-9.           31 min.   7 min.                       90    1, 3, 4  6
                          8                             30 sec.   20 sec.
                                  As per  D-7; painted with
                         5
          D-11          1 / ″     epoxy intumescent coating   36 min.  N/A                     90    1, 3, 4  35
                          8       including glass fiber rov-  25 sec.
                                  ing.
                         5
          D-12          1 / ″     As per D-4 with intumes-  37 min.  24 min.                   90    1, 3, 4  30
                          8       cent fire retardant paint.   30 sec.  40 sec.
                        1 / ″     As per D-4, except with 24
                         1
          D-13            2       ga. galvanized sheet metal   39 min.  39 min.                90    1, 3, 4  39
                        (nom.)
                                  facings.
                         5
          D-14          1 / ″     As per D-9.           41 min.   17 min.                      90    1, 3, 4,   20
                          8
                                                        30 sec.
                                                                  20 sec.
                                                                                                       6
          D-15           —        Class C steel fire door.   60 min.  58 min.                  90     7, 8  60
          D-16           —        Class B steel fire door.   60 min.  57 min.                  90     7, 8  60
                                  Solid core flush door; core
                                  staves laminated to facings
                                  but not each  other;  Birch
                         3
                                                     2
          D-17          1 / ″     plywood  facings  1 / ″  15 min.  13 min.                    37      11   13
                          4       rebate in door  frame for
                                  door;   3 / ″  clearance
                                          32
                                  between door and  wood
                                  frame.
                                                        (continued)




         284                                                            2018 INTERNATIONAL EXISTING BUILDING CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   298   299   300   301   302   303   304   305   306   307   308