Foundation requirements
Technical instruction no: 1000-0041 (Requirements for arrangement surface of INNIO
Jenbacher installations)
Installation surface:
capable to withstand static and dynamic load of INNIO Jenbacher plants
Static load = Plant weight (filled condition)
Dynamic load = ≤ 3% of plant weight
size of the installation surface is:
frame length + 200 mm [7,874 in]) x (frame width + 200 mm [7,874in]
flatness requirement for the installation surface of the installation
is ±1.5 mm/m with a maximum of is ± 5 mm
measured across the entire arrangement surface