Page 157 - Proceedings of 1st ISCIR 2017
P. 157
Strengthening of RC Structures using FRPs
by Asst. Prof. Dr. Kittipoom Rodsin
Strengthening of non-ductile
column using FRP 150
100 1
50
Lateral Load (kN) 0
เสาไม่ได้เสริมกําลัง -250 -200 -150 -100 -50 0 50 100 150 200 250
-50
With FRP
-100 Without FRP
-150
Displacement (mm)
เสาที่เสริมกําลัง
Strengthening of RC Structures using FRPs
by Asst. Prof. Dr. Kittipoom Rodsin
Why GFPR?
1. Cheap with high tensile strength
Tensile strength and cost of glass fiber
Carbon fiber Glass fiber
Tensile Strength (MPa) 3500 2300
Young’s Modulus (GPa) 200 76
Thickness (mm) 0.111 0.350
Price per sq. m. (Bth) 1400 300
Tensile Strength Per Meter (Ton) 38.85 80.50
Price/Strength (Bth/Ton) 36.0 3.7
Price/(Tensile Strength x Young’s 0.18 0.04
Modulus)
“Innovative Seismic Strengthening System for Concrete Structures”
© 2017 | T Imjai & R. Garcia (Eds.)
-- 155 --