Page 263 - Shaping A Sustainable Future
P. 263

D)  Reduction of CO  Emission from Using
                                   2
                  Dishwashing Method Based on CMC
                  Value Yearly


            •  Average energy consumption for Desalination and
                NEWater process= 1.95 kWh/m 3

            •  Energy consumption of wastewater treatment =
                0.5 kWh/m 3


            •  CO  emission per electricity generated =
                   2
                   0.4085 kgCO /kWh
                           2
            i)   Total reduction of CO  emission for conserving
                                  2
                 36,500L water and 36,901.5L of wastewater in
                 coffee shops yearly

                 (36.50m  x 1.95kWh/m  x 0.4085 kgCO /kWh) +
                      3
                                   3
                                                 2
                 (36.9015 m  x 0.5 kWh/m  x 0.4085 kgCO /kWh) =
                         3
                                      3
                                                   2
                 36.6 kgCO
                        2
            ii)   Total reduction of CO  emission for conserving
                                   2
                   3,650,000L water and 3,690,150L of wastewater
                   for Coffee Shops in Tampines yearly
                   (3650m  x 1.95kWh/m x 0.4085 kgCO /kWh) +
                                    3
                       3
                                                  2
                   (3690.15 m x 0.5 kWh/m  x 0.4085 kgCO /kWh) =
                          3
                                      3
                                                    2
                  3661kgCO 2












                                                              261
   258   259   260   261   262   263   264   265   266   267   268