                         2  Specify the number of Trimmers to be   located in a concrete or masonry wall, stem
                            generated on each side of the selected   wall, or garage curb. See “Wall Type
                        door.                                   Definitions” on page 383.
                         3  Rough Opening - Specify the amount   •  Uncheck Show in Plan to suppress the
                            to add to Each Side, the Top and the   display of the concrete cutout in plan
                        Bottom for the door’s framed rough opening.   views. A concrete cutout will only dis-
                        The rough opening should be large enough to   play in plan views if it is located in a
                        accommodate the door frame and space for   garage curb. See “In Plan Views” on page
                        shims. Window frames do not need to be     535.
                        included in the rough opening: only shim    Sill - When the bottom of a door is
                        space. If the Bottom Rough Opening value is   5  raised sufficiently off the floor, it will
                        greater than the Floor to Bottom value, the   require a sill as part of its framing.
                        difference is added to the top of the rough
                        opening when framing is built.          •  Specify the vertical Thickness of the sill.
                                                                •  Check Double Sill to generate two sill
                         4  Add for Concrete Cutout - Specify      members of the specified thickness
                            the amount to add to Each Side of the
                        door opening when the upper part of the door   instead of one.
                        is in a framed wall and the lower part is

                                                  Energy Values Panel
                        The settings on the ENERGY VALUES panel   REScheck. See “Export to REScheck” on
                        let you specify information used for export to   page 1199.