Page 828 - Chief Architect Reference Manual
P. 828

Chief Architect X10 Reference Manual



                           ing roof plane meets the dormer front wall   ceiling in the dormer. If you check this
                           exterior to the top plate of the dormer   option, you should define the dormer on
                           roof’s bearing walls.                  the floor above the room it is positioned
                                                                  over. If this room has a flat ceiling, check-
                        This top height is called the dormer ceiling   ing this option makes a hole in the ceiling
                        height, even if the ceiling in the dormer is not   under the dormer. This option should nor-
                        flat. The top dormer window casing is     mally be left unchecked.
                        usually close to this height.
                        • Check Set to Existing Ceiling to assign   Only available in the Dormer Defaults
                           the ceiling height of the room behind the   dialog, if Set Inside Window Trim Width is
                           dormer to the dormer. Not available in the   checked, the inside casing width for dormer
                           Dormer Defaults dialog.              windows defaults to the Inside Window
                                                                Trim value entered below. Dormer windows
                        • Height to Reach Existing shows the dif-  can appear too narrow on the outside due to
                           ference between the dormer height where   the space required for the inside casing to
                           the inside of the wall meets the underside   clear the inside surfaces of the side walls.
                           of the roof and the ceiling of the room   This value sets the width for the inside casing
                           behind it.                           of the dormer window.
                        • Specify the dormer’s Width, measured
                           from the outside surfaces of the dormer       Line Style Panel
                           side walls.
                                                                For information about the settings on this
                        • Form Room Inside Dormer is used only   panel, see “Line Style Panel” on page 301.
                           for floating dormers and creates a flat



                   Roof Returns and Other Details

                        Chief Architect offers a selection of tools to
                        add architectural details to your roof design.

                                   Boxed Eaves

                        Boxed eaves have a flat, horizontal soffit
                        surface instead of a soffit that follows the
                        underside of the rafter ends. Boxed eaves can
                        either extend out to the gable fascia or build
                        flush with the adjacent exterior wall.


                                                                   Boxed Eave         Flush Eave
                                                                You can specify Boxed Eaves for all roof
                                                                planes in the Build Roof dialog and for



                   828