Page 300 - HILTI
P. 300
Anchors Systems
Standard tool-set flush anchor (SS316) HKD-SR
Key applications and advantages Technical data
■ For medium-duty loads with anchor Head configuration Inner thread
bolts and threaded rods, e.g. sus-
Environmental Outdoor
pension systems for pipes, air ducts, conditions
sprinkler systems etc.
Type of fastening Pre-fastening
■ For redundant applications in cracked
concrete or single-point applications in Material Steel, A4 (SS316)
uncracked concrete composition
■ Available in a variety of sizes for maxi- Installation All
mized coverage of applications direction
■ Visual check for correct setting when Suitable for Yes
used with Hilti setting tool cracked concrete
with redundant
fastenings
PROFIS software Yes
Material, corrosion Steel, stainless
Accessories HSD-M, HSD-G
Ordering designation Internal Base Max. Packaging Anchor Thread Useable Package contents Sales pack Item number
thread size plate tightening length length thread quantity
clear- torque length
ance
hole
HKD-SR M6x25 6 mm 7 mm 4 Nm Box 25 mm 12 mm 12 mm 1x Flush anchor HKD-SR M 6x25 100 pc 247951
HKD-SR M8x30 8 mm 9 mm 8 Nm Box 30 mm 15 mm 15 mm 1x Flush anchor HKD-SR M 8x30 100 pc 247952
HKD-SR M10x40 10 mm 12 mm 15 Nm Box 40 mm 18 mm 18 mm 1x Flush anchor HKD-SR M10x40 50 pc 247953
HKD-SR M12x50 12 mm 14 mm 35 Nm Box 50 mm 22 mm 22 mm 1x Anchor HKD-SR M12X50 50 pc 247954
HKD-SR M16x65 16 mm 18 mm 60 Nm Box 65 mm 31 mm 31 mm 1x Flush anchor HKD-SR M16x65 25 pc 247955
HKD-SR M20x80 20 mm 22 mm 120 Nm Box 80 mm 42 mm 42 mm 1x Anchor HKD-SR M20X80 25 pc 247956
Economical manual flush-set anchor without lip (carbon steel) HKV
Key applications and advantages Technical data Anchors
■ For use with bolts or threaded rods, e.g. Head configuration Inner thread
suspension systems for pipes, ducts, Environmental Indoor, dry conditions
sprinkler systems, etc.
conditions
■ No damage to inner thread when tap- Type of fastening Pre-fastening
ping in or setting
■ No collar – can be set at greater depth Material Steel, zinc-plated (min.
composition 5 µm)
■ Visual check for correct setting when
used with Hilti HSD-G and HSD-B Installation All
setting tools direction
Material, corrosion Steel, zinc-plated
Accessories HSD-M, HSD-G
Internal thread size 6 mm
Ordering Thread Base plate Max. Packaging Anchor Thread Useable Package contents Sales pack Item number
designation engage- clearance tightening length length thread length quantity
ment hole torque
depth
- max.
HKV M6x25 13 mm 7 mm 3 Nm Bag 25 mm 13 mm 13 mm 1x Flush anchor HKV M6x25 assy 100 pc 384616
www.hilti.group 291