Page 178 - 8.5X11__AZ_VERSION_2_9-12-07
P. 178

COMPRESSED-AIR SPRAYER EQUIPMENT                                                                                          COMPRESSED-AIR SPRAYER EQUIPMENT


                                                         (Courtesy of UNIVAR)                                                                                                       (Courtesy of UNIVAR)


                   A compressed-air sprayer is just what you would expect-- when you pump it, air goes into                                  A compressed-air sprayer is just what you would expect-- when you pump it, air goes into
                   the pump cylinder and into a reservoir tank.  It only takes 15-20 pumps to pressurize the                                 the pump cylinder and into a reservoir tank.  It only takes 15-20 pumps to pressurize the
                   tank to about 20 psi, which is the proper pressure for most applications.  If you have to                                 tank to about 20 psi, which is the proper pressure for most applications.  If you have to
                   pump much more than that, or have to re-pump every few minutes to keep up the pressure,                                   pump much more than that, or have to re-pump every few minutes to keep up the pressure,
                   your spray tank is not working properly.  There are several parts to check that could fix the                             your spray tank is not working properly.  There are several parts to check that could fix the
                   problem.                                                                                                                  problem.


                   PLUNGER CUP                                                                                                               PLUNGER CUP


                   If you push on the handle and feel no resistance, or you hear no air going into the tank,                                 If you push on the handle and feel no resistance, or you hear no air going into the tank,
                   there may be a problem with the plunger cup.  Some sprayers have plunger cups made of                                     there may be a problem with the plunger cup.  Some sprayers have plunger cups made of
                   leather.  They can be treated with NEET’S-FOOT OIL.  Thoroughly rub it into the leather.  If                              leather.  They can be treated with NEET’S-FOOT OIL.  Thoroughly rub it into the leather.  If
                   that does not take care of the problem, go ahead and replace the plunger cup.                                             that does not take care of the problem, go ahead and replace the plunger cup.

                   For sprayers with plastic plunger cups, the only thing you can do is replace it.  If the tank is                          For sprayers with plastic plunger cups, the only thing you can do is replace it.  If the tank is
                   slightly dented, replacing with a leather plunger cup may seal the problems.  If the dents are                            slightly dented, replacing with a leather plunger cup may seal the problems.  If the dents are
                   too severe, there is not much you can do to make the seal work again.                                                     too severe, there is not much you can do to make the seal work again.

                   PUMP CHECK VALVE                                                                                                          PUMP CHECK VALVE


                   The pump check valve is used to prevent water from going back into the cylinder while al-                                 The pump check valve is used to prevent water from going back into the cylinder while al-
                   lowing air to be pushed out of the pump.  If the inside of the pump cylinder is wet, it could be                          lowing air to be pushed out of the pump.  If the inside of the pump cylinder is wet, it could be
                   that the rubber valve is clogged and/or not sealing.  If it is clogged, it is a simple matter of                          that the rubber valve is clogged and/or not sealing.  If it is clogged, it is a simple matter of
                   just cleaning it.  Sometimes they are quite worn or cracked, and will have to be replaced.                                just cleaning it.  Sometimes they are quite worn or cracked, and will have to be replaced.


                   TANK GASKET SEALING RING                                                                                                  TANK GASKET SEALING RING

                   The pump cylinder fits to the top of the tank with a gasket.  This gasket is a ring that seals                            The pump cylinder fits to the top of the tank with a gasket.  This gasket is a ring that seals
                   the tank.  If air is being forced into the tank, but there is still no pressure, check the tank                           the tank.  If air is being forced into the tank, but there is still no pressure, check the tank
                   gasket sealing ring for cracks.  They are also easy to replace when worn out.                                             gasket sealing ring for cracks.  They are also easy to replace when worn out.