Page 46 - LPS Food Grade Approved Products - All Task Solutions 2019
P. 46

6.3. Methods and material for  Refer to attached safety data sheets and/or instructions for use. Stop leak if you can do so without
        containment and cleaning up  risk. Use water spray to reduce vapours or divert vapour cloud drift. Isolate area until gas has
                                     dispersed. Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area).
                                     Keep combustibles (wood, paper, oil etc) away from spilled material.
                                     Large Spills: Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or
                                     earth and place into containers. Scoop up used absorbent into drums or other appropriate
                                     container. Following product recovery, flush area with water.
                                     Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
                                     remove residual contamination.
                                     Never return spills to original containers for re-use.
        6.4. Reference to other      Use personal protection recommended in Section 8 of the SDS. For waste disposal, see section
        sections                     13.
        SECTION 7: Handling and storage

        7.1. Precautions for safe    Pressurised container:  Do not pierce or burn, even after use. Do not use if spray button is missing
        handling                     or defective. Do not spray on a naked flame or any other incandescent material Do not smoke
                                     while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or
                                     expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when
                                     handling the product must be grounded. Avoid contact with eyes, skin, and clothing. Avoid
                                     prolonged exposure. Use only in well-ventilated areas. Wear appropriate personal protective
                                     equipment. Observe good industrial hygiene practices.
        7.2. Conditions for safe     Level 1 Aerosol.
        storage, including any
        incompatibilities            Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50°C.
                                     Keep away from heat, sparks and open flame. This material can accumulate static charge which
                                     may cause spark and become an ignition source. Prevent electrostatic charge build-up by using
                                     common bonding and grounding techniques. Store in original tightly closed container. Store away
                                     from incompatible materials (see Section 10 of the SDS).
        7.3. Specific end use(s)     Not available.
        SECTION 8: Exposure controls/personal protection
        8.1. Control parameters
        Occupational exposure limits
            Germany. DFG MAK List (advisory OELs). Commission for the Investigation of Health Hazards of Chemical Compounds
            in the Work Area (DFG)
            Components                           Type                         Value
            Naphtha, Petroleum,                  TWA                          300 mg/m3
            Hydrotreated Heavy (CAS
            64742-48-9)
                                                                              50 ppm
            Romania. OELs. Protection of workers from exposure to chemical agents at the workplace
            Components                           Type                         Value
            Poly (Dimethylsiloxane)              STEL                         300 mg/m3
            (CAS 63148-62-9)
                                                 TWA                          200 mg/m3
            Switzerland. SUVA Grenzwerte am Arbeitsplatz
            Components                           Type                         Value
            Naphtha, Petroleum,                  STEL                         600 mg/m3
            Hydrotreated Heavy (CAS
            64742-48-9)
                                                                              100 ppm
                                                 TWA                          300 mg/m3
                                                                              50 ppm
        Biological limit values      No biological exposure limits noted for the ingredient(s).
        Recommended monitoring       Follow standard monitoring procedures.
        procedures
        Derived no effect levels     Not available.
        (DNELs)
        Predicted no effect          Not available.
        concentrations (PNECs)

        8.2. Exposure controls

         Material name: LPS® Heavy-Duty Silicone (Aerosol) - ITW Pro Brands (EU)                               SDS EU
         01516, M01516    Version #: 03    Revision date: 12-May-2017    Issue date: 15-October-2015            4 / 9
   41   42   43   44   45   46   47   48   49   50   51