6.3. Methods and material for Refer to attached safety data sheets and/or instructions for use. Stop leak if you can do so without
containment and cleaning up risk. Use water spray to reduce vapours or divert vapour cloud drift. Isolate area until gas has
dispersed. Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area).
Keep combustibles (wood, paper, oil etc) away from spilled material.
Large Spills: Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or
earth and place into containers. Scoop up used absorbent into drums or other appropriate
container. Following product recovery, flush area with water.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination.
Never return spills to original containers for re-use.
6.4. Reference to other Use personal protection recommended in Section 8 of the SDS. For waste disposal, see section
sections 13.
SECTION 7: Handling and storage
7.1. Precautions for safe Pressurised container: Do not pierce or burn, even after use. Do not use if spray button is missing
handling or defective. Do not spray on a naked flame or any other incandescent material Do not smoke
while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or
expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when
handling the product must be grounded. Avoid contact with eyes, skin, and clothing. Avoid
prolonged exposure. Use only in well-ventilated areas. Wear appropriate personal protective
equipment. Observe good industrial hygiene practices.
7.2. Conditions for safe Level 1 Aerosol.
storage, including any
incompatibilities Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep away from heat, sparks and open flame. This material can accumulate static charge which
may cause spark and become an ignition source. Prevent electrostatic charge build-up by using
common bonding and grounding techniques. Store in original tightly closed container. Store away
from incompatible materials (see Section 10 of the SDS).
7.3. Specific end use(s) Not available.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Occupational exposure limits
Germany. DFG MAK List (advisory OELs). Commission for the Investigation of Health Hazards of Chemical Compounds
in the Work Area (DFG)
Components Type Value
Naphtha, Petroleum, TWA 300 mg/m3
Hydrotreated Heavy (CAS
64742-48-9)
50 ppm
Romania. OELs. Protection of workers from exposure to chemical agents at the workplace
Components Type Value
Poly (Dimethylsiloxane) STEL 300 mg/m3
(CAS 63148-62-9)
TWA 200 mg/m3
Switzerland. SUVA Grenzwerte am Arbeitsplatz
Components Type Value
Naphtha, Petroleum, STEL 600 mg/m3
Hydrotreated Heavy (CAS
64742-48-9)
100 ppm
TWA 300 mg/m3
50 ppm
Biological limit values No biological exposure limits noted for the ingredient(s).
Recommended monitoring Follow standard monitoring procedures.
procedures
Derived no effect levels Not available.
(DNELs)
Predicted no effect Not available.
concentrations (PNECs)
8.2. Exposure controls
Material name: LPS® Heavy-Duty Silicone (Aerosol) - ITW Pro Brands (EU) SDS EU
01516, M01516 Version #: 03 Revision date: 12-May-2017 Issue date: 15-October-2015 4 / 9