Page 46 - FreEsStyler® E-1032 Programming and Operation Manual
P. 46

E-1032 PROGRAMMING AND OPERATION


            Chapter 5 Faults and Alarms


            Drive Code Overview

                The DRIVE CODE displays recorded VFD (Variable Frequency  Drive) alarms. There  are  two separate fields of
                information. The two numbers on the right displays the most current alarm. The two numbers on the left displays the
                previously recorded alarm as shown below.
                    Left Two      Right Two
                    Numbers       Numbers
                           31 B1
                  Previous Alarm:   Existing Alarm:
                  Motor Overload   Communication
                                  Leave Fault
                Drive Codes
                           Numerical        Code
                            Display      Abbreviation          Alarm Description
                              10             OC1         OVER CURRENT DURING ACCELERATION
                              11             OC2         STEADY SPEED OVER CURRENT
                              12             OC3         OVER CURRENT DURING DECELERATION
                              20             OV1         OVER VOLTAGE DURING ACCELERATION
                              21             OV2         STEADY SPEED OVER VOLTAGE
                              22             OV3         OVER VOLTAGE DURING DECELERATION
                              30             THT         INVERTER OVERLOAD
                              31             THM         MOTOR OVERLOAD
                              40             FIN         HEAT SINK OVERTEMP
                              60             OLT         STALL PREVENTION STOP
                              70              BE         BRAKE TRANSISTOR FAULT
                              80             GF          GROUND FAULT
                              81              LF         OPEN PHASE FAILURE
                              90             OHT         EXTERNAL THERMAL RELAY
                              A0             OPT         OPTION FAULT
                              B0              PE         CORRUPT MEMORY
                              B1             PUE         COMMUNICATION LEAVE FAULT
                              B2             RET         RETRY COUNT EXCEEDED
                              C2             P24         PR. 24 ALARM
                              F3             E. 3        FAULT 3
                              F6             E. 6        FAULT 6
                              F7             E. 7        FAULT 7





















            5-4                 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681                    1MANUL226