Chapter 3 General Repairs
Water Softener
Component Functionality
Brine Tank
Included with a standard system is a brine make-up tank. These tanks will
accommodate loading of softener grade salt and provide water to dissolve
brine into a saturated liquid form.
Softened water is delivered to the brine tank by the control valve during
the normal regeneration sequence.
Brine tanks include an overflow connection to allow for a safety in case of
tank overflow.
Also included with the brine tank is the brine valve. The brine valve is
used to adjust the volume of brine to be produced for each cycle.
For a multiple system installation, one standard brine tank is required for
each control valve.
Central Brine System
For larger, multiple systems, a Central Brining System
alternative is available. This will replace the need for multiple
brine tanks when installing multiple units in parallel.
The Central Brining System has features similar to the
independent brine tanks; however, to accommodate multiple
systems, the brine refill is accomplished by a float mechanism
attached to the softened water supply outlet of the system.
A check valve must be added to each softener on the brine line
for the unit to operate properly with the Central Brining System.
Depending on the CP unit selected, the Venturi Throat and
Brine Flow Control may need to be changed.