Page 23 - Kondor® KL 2 - E-1063 Programming and Operation Manual
P. 23
®
KL2: 1063 PROGRAMMING AND OPERATION
Chapter 3 Operator Interface/Programming
Setup
Setup / Application Setup
E-1063 Screen Key
· Columns FILL, DWELL and PURGE are measured in seconds.
· Values may be changed in increments of tenths of a second.
· Reclaim: Toggles between YES/NO to select the Reclaim Output on
or off per application
· Tank: Toggles between SMALL/LARGE to select the desired tank per
application
· Enter OP Reclaim: Toggles between Enabled/Disabled to select the
Reclaim Output on or off during Entrance Operation
Fill Time: Delays motion while the application is filling.
Dwell Time: Delays starting the next pass to allow chemical to soak on the vehicle longer. Typically the speed of
the Return Pass determines the soak time of the chemical.
Purge Time: Delays starting the next pass while turning on the Purge Air. Presoaks turn on the Purge Air during
B/F IN MOTION. All other options turn on the Purge Air once B/F IN MOTION is complete.
Note: Setting the Purge timer too large will unnecessarily add to Cycle Time.
PREFILL: This feature is used to reduce the cycle time and save costs for utilities. In general, Pre-Fill will use the
next application to finish dispensing the current application. Pre-Fill will only function if the following conditions are
true:
· Pump Speeds are in the same zone
· Both passes use Reclaim or both do not use Reclaim
· Both passes use the small tank or both passes do not use the small tank
· First (current) pass does not have a Purge Time
· First (current) pass does not have a Dwell Time
· Both passes are of the same type as selected by Center = “________” in the Application Configuration screen
Setup / Advanced Configuration
See Chapter 4.