                      Setup

                          Setup / Application Setup

                                           E-1063                                 Screen Key
                                                               ·  Columns FILL, DWELL and PURGE are measured in seconds.
                                                               ·  Values may be changed in increments of tenths of a second.
                                                               ·  Reclaim: Toggles between YES/NO to select the Reclaim Output on
                                                                 or off per application
                                                               ·  Tank: Toggles between SMALL/LARGE to select the desired tank per
                                                                 application
                                                               ·  Enter OP Reclaim: Toggles between Enabled/Disabled to select the
                                                                 Reclaim Output on or off during Entrance Operation



                             Fill Time: Delays motion while the application is filling.

                             Dwell Time: Delays starting the next pass to allow chemical to soak on the vehicle longer. Typically the speed of
                             the Return Pass determines the soak time of the chemical.

                             Purge Time: Delays starting the next pass while turning on the Purge Air. Presoaks turn on the Purge Air during
                             B/F IN MOTION. All other options turn on the Purge Air once B/F IN MOTION is complete.
                             Note:  Setting the Purge timer too large will unnecessarily add to Cycle Time.

                             PREFILL: This feature is used to reduce the cycle time and save costs for utilities. In general, Pre-Fill will use the
                             next application to finish dispensing the current application. Pre-Fill will only function if the following conditions are
                             true:
                               ·  Pump Speeds are in the same zone
                               ·  Both passes use Reclaim or both do not use Reclaim
                               ·  Both passes use the small tank or both passes do not use the small tank
                               ·  First (current) pass does not have a Purge Time
                               ·  First (current) pass does not have a Dwell Time
                               ·  Both passes are of the same type as selected by Center = “________” in the Application Configuration screen

                          Setup / Advanced Configuration

                             See Chapter 4.























                       1MANUL128                  Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681                 3-3