Page 642 - 2018 National Home Improvement
P. 642

2018 National Home Improvement Estimator, All Rights Reserved                                   Page 514



            Straighten a frame wall. Using wedge braces and jack posts to restore a wall to vertical alignment.
            Add the cost of removing and reinstalling wall finish materials, if required. Vertical jacks may be required
            to relieve the weight on a load-bearing wall. Add the cost of installing wall straps and shear panels once
            the wall is plumb.
              Set and remove diagonal brace, per brace      B3@.350   Ea         --    12.31      12.31
              Set and remove vertical jack, per jack        B3@.350   Ea         --    12.31      12.31
              Wedge the wall into vertical alignment,
               per LF of wall                               B3@.200   LF         --      7.03       7.03
              Straighten one stud, cut saw kerf and drive shim or screw into the kerf,
               reinforce with a plywood scab               BC@.300    Ea         --    12.08      12.08
              Remove and replace a badly warped stud       BC@.300    Ea      2.79     12.08      14.87
              Adjustable jack post, 20,000 lb., purchase     --@.000  Ea     84.84         --     84.84
            Wedge braces, 3 uses, #2 and better lumber
              2" x 4" x 12'                                 B3@.012   Ea      1.49       0.42       1.92
              2" x 6" x 12'                                 B3@.018   Ea      2.47       0.63       3.11

            Straighten a window opening. Remove a damaged window from a wood-frame wall opening and
            straighten the framed opening to accept a replacement window. Includes prying off window trim,
            removing the stops and sash, removing exterior finish to expose the jamb, pulling or cutting nails
            securing the window frame, lifting out the damaged window and restoring the opening to square with
            braces, extended bar clamps or corner clamps. Add the cost of straps, braces, the replacement window
            and patching the exterior wall finish.
              Remove an existing damaged window            BC@1.50    Ea         --    60.39      60.39
              Re-square the window frame and sill          BC@.500    Ea         --    20.13      20.13

            Plaster and stucco repair. Using hand tools and working from a ladder.
            Scribe cracked plaster or stucco to 1/4" depth and fill the crack with:
              Elastomeric caulk, per linear foot filled    CF@.033    LF         --      1.26       1.26
              Elastomeric patch and caulk, 10 oz. tube       --@.000  Ea      4.30         --       4.30
              Patch hole in exterior stucco. Chip and wire brush loose
              stucco, moisten surface, apply stucco patch with a
               trowel, per 4" x 4" patch                   CF@.250    Ea      0.57       9.55     10.11
              Premixed stucco patch, quart                   --@.000  Ea      8.26         --       8.26
              Touch-up painting to match                   PT@.333    Ea      4.88     13.68      18.56

            Gypsum drywall repair. Cost estimates for removing, repairing and replacing interior finishes appear in
            chapter 10 beginning on page 242.

            Fireplaces and chimneys. Cost estimates for removing, repairing and replacing fireplaces and
            chimneys appear in chapter 6 beginning on page 115.