Page 17 - SRL Diagnostics
P. 17

Serum
                        After clotting and centrifugation, transfer separated serum to a multipurpose vial
                        pre-labeled with patient's name. Please ensure that the serum is free from
                        hemolysis and turbidity.


                        Plasma
                        Please mention the anticoagulant in which blood was collected to obtain plasma, e.g.
                        EDTA plasma, Fluoride plasma Fasting or Post Prandial, etc.
                        Please mention the time of collection
                        Transfer separated to a multipurpose vial pre-labeled with patient's name.

                    IMP: Ensure that the plasma is free from hemolysis and turbidity
                        PLASMA FOR COAGULATION TEST

                       Blood is collected in a blue top vacutainer (refer to table on
                       page:16)
                       Collection of blood should be up to the mark specified on
                       vacutainer

                       The recommended proportion of blood to the sodium
                       citrate anticoagulant volume is 9:1. Inadequate or
                       overfilling of the tube will compromise this ratio, and may
                       lead to inaccurate results for calcium-dependent clotting
                       tests, such as the PT and aPTT.
                                                                                         Maximum Fill
                       If due to high hematocrit, e.g. (>60%), the volume of            Maximum Fill
                       plasma is low, the anticoagulant effect gets enhanced as a         Indicator
                       result of anticoagulant to plasma ratio. In such situations,
                       the blood has to be re-collected with a smaller
                       volume of the anticoagulant as per published guidelines.
                                                                            2.7ml
                       Hematocrit correction = 100 — HCT / 595 — HCT for 1 ml   Draw
                       of blood.                                            Tube
                                                                      13 mm x 75 mm
                       This plasma must be stored and transported in frozen   Full Draw
                       condition till the time of processing.









                                                                                                14
   12   13   14   15   16   17   18   19   20   21   22