Page 392 - 2019종합카다로그_Pressure gauge
P. 392

Pressure switch                            Working range
         A bi-stable electro mechanical device than actuates/  The maximum input pressure that can be continuously
         deactuates one or more electrical switching element at a  applied to the pressure switch without causing
         predetermined discrete pressure upon rising or falling.  permanent change of set point, leakage or material
                                                    failure.
         Adjustable range                           Max. Working pressure
         The span of pressure between upper and lower limits   The maximum input pressure that can be continuously
         within which the pressure switch can be adjusted to   applied to the pressure switch without causing leakage
         actuate/deactuate. It is expressed for increasing   or catastrophic material failure. Permanent change of
         pressure.                                  set point may occur, or the device may be rendered
                                                    inoperative.
         Setpoint
         That discrete pressure at which the pressure switch is  Repeatability
         adjusted to actuate/deactuate on rising or falling   The ability of a pressure switch to successively operate
         pressure. It must fall with the adjustable range and be   at a set point that is approached from a starting point
         called out as increasing.                  in the same direction and returns to the starting point
                                                    over three consecutive cycles to establish a pressure
                                                    profile.
         Dead band                                  The closeness of the measures set point values is
         The difference in pressure between the increasing set  normally expressed as a percentage of full scale
         point and the decreasing set point.        (maximum adjustable range pressure).









         Pressure range table


                                           Dead band                Flange
           Code   Adjustable setting range  One SPDT Two SPDT  Working  size  Max. Working pressure
                                                           range
                                       Setpoint  Setpoint           (mm)
                      bar       kPa           bar            bar      bar     bar     MPa
           900      -0.1 ~ -0.15-100 ~ -15  Within 10 %  Within 20 %  10  88 ~ 98  35  3.5
                                                  adjustable
                                        adjustable
           927    0.003 ~ 0.03  0.3 ~ 3   range    range      2       113      6       0.6
           930     0.02 ~ 0.07  2 ~ 7
           929    0.003 ~ 0.07  0.3 ~ 7
           901    0.075 ~ 0.15  7.5 ~ 15
           938    0.045 ~ 0.3  4.5 ~ 30                      10     88 ~ 98
           941    0.075 ~ 0.5  7.5 ~ 50                                       35       3.5
           949     0.09 ~ 0.6  9 ~ 60
           942     0.12 ~ 0.8  12 ~ 80
           902     0.15 ~ 1   15 ~ 100                       20       63
           903      0.3 ~ 2   30 ~ 200  Within 5 % Within 10 %
           904     0.45 ~ 3   45 ~ 300  adjustable  adjustable
                                         range
                                                   range
           906      0.9 ~ 6   90 ~ 600
           908      1.5 ~ 10  0.15 ~ 1 MPa                                    70        7
           911     2.25 ~ 15  0.225 ~ 1.5 MPa                50
           912       3 ~ 20  0.3 ~ 2 MPa                              60
           914      4.5 ~ 30  0.45 ~ 3 MPa                                    170      17
           916      7.5 ~ 50  0.75 ~ 5 MPa                   100
           918      8.5 ~ 70  0.85 ~ 7 MPa                                    200      20
           919     10.5 ~ 100  1.05 ~ 10 MPa                 150
           926     15.5 ~ 150  1.55 ~ 15 MPa                                  400      40



       P945_04
   387   388   389   390   391   392   393   394   395   396   397