Page 5 - 2019종합카다로그_Thermocouple & RTD
P. 5

5. Typical resistance of standard thermocouple  Non-metallic tubes
                                   Ref : JIS C 1602  * Hoskins unit: /m
                     Type  B  R  S   K   E   J    T   N*       Material     Symbol   Operating temp. (℃)
               AWG wire  Old JIS type  PR  CA  CRC  IC  CC
               dia. (mm)                                    Recrystallized  GK-SIC       1,600
               28  0.32                          6.17  16.43  silicon carbide
               24  0.50  1.75  1.47  1.43              6.50  Self-bonded    SI-SIC       1,650
               22  0.65             2.95  3.56  1.70  1.50  4.08  silicon carbide
               18  1.00             1.25  1.50  0.72  0.63  1.62  Clay-bonded  Y3-SIC    1,500
               14  1.60             0.49  0.59  0.28  0.25  0.64  silicon carbide
               11  2.30             0.24  0.28  0.14     0.32  Recrystallized  SSA-S     1,600
                8  3.20             0.12  0.15  0.07     0.13  alumina
               Note. Resistance at 0℃ (Ro) measured between (+) and (-) legs.  Mulite  HB  1,500

               6. Operating and maximum temperature limits  8. Sheathed thermocouple
                         Wire diameter  Operating temp.  Maximum limit  Sheathed Thermocouple is one sheathed thermocouple
                 Type
                           (mm)     Limit (℃) (1)  (℃) (2)  that is composed of a fine gauged metal sheath in which
                  B        0.50       1,500      1,700    high purity MgO powder is tightly compacted around
                  R        0.50       1,400      1,600    thermoelement wires.
                                                          Sheathed thermocouple has high insulation and pressure
                  S        0.50       1,400      1,600    resistance. It has also high reliability because of its EMF
                           0.65        650        850     tolerance falling within the limits stipulated by JIS, ANSI,
                           1.00        750        950     BS, DIN, etc.
                  K        1.60        850       1,050
                           2.30        900       1,100    Features
                           3.20       1,000      1,200    ¥ •  Quick response:
                                                             By virtue of its integrated structure composed of
                           0.65        450        500        thermoelement wires insulating material and a
                           1.00        500        550        protection tube, one has very quick response to
                  E        1.60        550        650        temperature change.
                           2.30        600        750     ¥ •  High flexibility and mechanical strength:
                           3.20        700        800        With its tightly compacted from, sheathed
                           0.65        400        500        thermocouple has mechanical strength and pliability up
                           1.00        450        550        to bending radius equal to 2 time of the sheath O.D
                  J        1.60        500        650     ¥ •  Excellent resistance to heat Corrosion and Pressure
                                                             As high purity MgO powder is tightly compacted in a
                           2.30        550        750        heat resistant metal tube, Sheath thermocouple is
                           3.20        600        750        highly gas-tight, no corrosion from surrounding
                           0.32        200        250        atmospheres and withstand high pressures up to
                           0.65        200        250        500 kg / cm².
                  T        1.00        250        300     ¥ •  Wide selection of cable specifications :
                           1.60        300        350        From very fine gauge of 0.25 mm to 12.7 mm in O.D.
                           1.60        900       1,100       and up to 300 meters in length are available.
                  N        2.30       1,100      1,200       Thermoelement wires of 2-pair and 3-pair are also available.
                           3.20       1,200      1,300
               Note :  1. Operating temperature limit means the upper temperature, where
                              thermocouple can be used continuously in air.
                          2. Maximum limit means the upper temp, where thermocouple can be
                              used temporarily owing to inevitable circumstances.
               7. Protection tubes
               Metallic tubes
                    Material  Operating temp. (℃)  Maximum temp. (℃)
                  304SS            900          1,000
                  316SS            900          1,000
                  321SS            900          1,000
                  310SS            950          1,050
                  347SS            900          1,000
                  446SS           1,050         1,125
                  Inconel 600     1,180         1,250
                  Inconel 800      870          1,000
                  Hastelloy-C     1,000         1,100
                  Hastelloy-B      800          1,100
                  Titanium     Oxi.250 red.1,000
                  Monel            500           600
                  Tantalum     Oxi.300 red.2,200
                  A182 F11         565
                  A182 F22         593




                                                                                       Thermocouple & RTD_05