Page 25 - Best Practice for Construction Projects
P. 25

Welding stations



                 •    All weld stations must have full 360˚ weld screen protection
                      to protect pedestrians from weld spark and arc flashes.

                 •    All weld stations must have adequate fire extinguishers, fire
                      blanket, fire watch personnel and flame retardant clothing.
                 •    The minimum fire watch after hot works is completed is 30
                      minutes.
                 •    All weld stations must be kept clean and free from redundant
                      material to prevent fire hazards and trip hazards.

                 •    Always check the area where you are carrying out hot works
        2. Equipment  •  fire blankets.
                      to ensure no flammable material is in the vicinity. Where
                      combustibles can’t be removed they must be protected with



                      Clamp / secure the material you are welding. Ensure your
                      weld bench is at waist level.

                 •
                      A hot works permit is required for all welding activities.
                 •
                      Check all welding equipment before use, inspect for any
                      damage to hoses and connections.
                 •    All gas cylinders must be secured to a suitable trolley.
                 •    Full weld PPE must be worn when welding

                 •    Corriboard is not a fire rated weld screen! Do not use it as a
                      fire screen.










     8             Visual Standards | Feb. 2019