Page 16 - GODEL CONCRETE & SYSTEMS INCORPORATED
P. 16

MAURER Expansion Joints                                                                                                 MAURER Tuned Mass Dampers


   Roadway expansion joints on bridges reliably                                                                            Civil engineering structures may be prone to large-amplitude
   absorb continuous traffic loads in structures,                                                                          vibrations due to wind and earthquake loading mechanisms
   including movements caused by shrinkage/creeping                                                                        because of their slenderness and low inherent damping ratio
   or temperature variations. These movements are                                                                          of approx. 1%. MAURER offers different types of Tuned Mass
   enabled in any direction and structural gaps are                                                                        Dampers (TMD) to considerably enhance both comfort and
   covered at any load. Compared to road bridges,                                                                          structural stability.
   railroad bridges face different challenges, because
   the trains that pass bridges cause higher traffic loads.                                                                >> TYPES OF VIBRATION
   MAURER Seismic Joints are expansion joints with                                                                         Wind loading mechanisms which may evoke large resonance
   reserves for extreme situations. MAURER Architectural                                                                   and therefore large-amplitude oscillations in high-rise
   Joints optically adapt to the esthetics of the building.                                                                buildings impair the comfort and lead to malaise (seasickness).
                                                                                                                           Free vibrations of tall buildings after earthquake excitation
                                                                                                                           may cause low-cycle fatigue.


                                                                                                                           Bending, torsional galloping and flatter vibrations in bridges
                                                                                                                           lead to large-amplitude and therefore dangerous resonant
                                                                                                                           vibrations that may even destroy the deck structure.
                                                                                                                           Human-induced vibrations in stadiums, floors and footbridges
                                                                                                                           may yield vibration amplitudes that are beyond the
                                                                                                                           acceptable maximum values for comfort and safety.





                                                                                                                                                                     The MAURER factory team
                                                                                                                                                                   illustrates the dimension of the
                                                                                                                                                                   steel frame for the double pen-
                  Installation of MAURER Modular Expansion                                                                                                        dulum of SOCAR Tower in Baku /
                          Joint for Izmit Bay Bridg                                                                                                                        Azerbaidjan



    Key characteristics of MAURER Expansion Joints

    - Maintenance-free, watertight and fatigue-resistant
    - Certified external quality management                                                                                 Key characteristics of MAURER Tuned Mass Dampers
    - Certified life span 20 to 50 years
    - Suitable for any movements from 5 to 5.000 mm >                                                                       - Single-source solution: modelbased optimal design of
    - Expansion joints are approved by Deutsche Bahn and the                                                                TMD within structure, minimizing TMD size
      Federal Ministry of Transport and Digital Infrastructure                                                              - External testing
    - CE marking available for various types                                                                                - Installation and adjustment Increased efficiency by up
                                                                                                                            to 20% compared to customary mass dampers leads to
                                                                                                                            cost reduction and increase of reliability












    2001 Mabini St, Malate, Manila, 1004 Metro Manila
    +632 253 - 3016
    http://www.gcs.com.ph/
   11   12   13   14   15   16   17   18   19   20