Page 195 - DelcoSalesPlayBook2020!
P. 195
Dimensions
1 /2" LFe480 / LFG480 3 /8" LFe480 / LFG480 Quick-Connect LFe480 / LFG480
3 /16"
3 3 3/16 /16" 3 9/16 9
3
2 /16" (81 mm) (91 mm)
15
[81 mm]
[91 mm]
2 15/16
(74 mm)
[74 mm]
1
1 1 1/4 /4" 1 1 1/4 /4"
1
1
1 /4" (32 mm) (32 mm)
[32 mm]
1 1/4
[32 mm]
(32 mm)
[32 mm]
5
1 /8" 2 /16"
7
2 5/16
[59 mm]
1 7/8
1 1 5/8 /8" (47 mm) 11 (59 mm) 4 4 11/16 /16"
5
11
[47 mm]
3 11/16
(41 mm) 3 /16" (119 mm)
[119 mm]
[41 mm]
[94 mm]
3 3/16 /16" (94 mm)
3
3
(81 mm)
[81 mm]
SINGLE LAVATORY
Piping Diagram MULTIPLE LAVATORY
POWERS e480 or LFe480
POWERS LFG480 or LFe480
POWERS e480 or LFe480 (w/INTEGRAL CHECKS)
(w/integral checks)
(w/INTEGRAL CHECKS)
M M
POWERS LFG480 OR
POWERS UTC
C
VALVE
H C H LFe480 VALVE
RECIRCULATION COLD
WATER
POWERS UTC COLD WATER SUPPLY
VALVE SUPPLY
HEAT COLD WATER
TRAP SUPPLY HEAT EXPANSION
TRAP WATER AQUASTAT TANK
EXPANSION HEATER COLD WATER
TANK SUPPLY
WATER HEATER WATER HEATER SOURCE
HEAT
SOURCE WATER EXPANSION
TRAP HEATER TANK HEAT
TRAP
Ordering Code EXPANSION
TANK
Order Code WATER HEATER SOURCE
0.25 gpm minimum flow LFG480
0.50 gpm minimum flow LFE480
½" NPT Rough Bronze Finish 00
½" NPT Chrome Plated Finish 01
3 ∕8" Compression Rough Bronze Finish 10
3 ∕8" Compression Chrome Plated Finish 11
3 ∕8" Quick-Connect Rough Bronze Finish 50
3 ∕8" Quick-Connect Chrome Plated Finish 51 POWERS UTC
VALVE
Typical Specification WATER
COLD
Lavatory tempering valve shall be ASSE 1070 and cUPC listed. material which shall comply with state codes and standards, SUPPLY
C
All internal components shall be from corrosion resistant material. where applicable requiring reduced lead content. Control tem-
AQUASTAT
The valve must control each performance standard down to 0.25 LTHW perature must be adjustable between 80–120° F (32–43°C) with
T
(OPTIONAL)
a locking nut to prevent unauthorized or accidental adjustment.
gpm (1.00 lpm) for LFG480 and 0.5 gpm (1.90 lpm) for LFe480. RETURN EXPANSION
POWERS UTC
TANK
Capacity of the valve must be 3 gpm (11 lpm) @ 45psi differen- The valve shall contain integral checks to prevent cross flow and
VALVE
HEAT
tial or 4 gpm (15 lpm) @ 45psi differential. Thermostatic lavatory inlet screens to filter debris. The valve shall be a Powers Series
WATER
LFe480 or LFG480.
tempering valve shall be constructed using Lead Free* brass COLD WATER TRAP HEATER
SUPPLY
HEAT EXPANSION
WATER
TRAP HEATER TANK
C
HTHW RETURN T
AQUASTAT USA: Tel: (800) 669-5430 • Fax: (847) 229-0526 • PowersControls.com
(OPTIONAL) Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • PowersControls.ca
Latin America: Tel: (52) 81-1001-8600 • PowersControls.com
ES-P-LFe480_LFG480 1905 © 2019 Powers
T TEMP/PRESSURE GAUGE
FLOW DIRECTION
CHECK VALVE
BALL VALVE
AUTOMATIC BALANCING VALVE
C CIRCULATOR