Page 60 - DelcoSalesPlayBook2020!
P. 60
CLEAN-SEAL PLUGS
®
Designed for stack testing of drain, waste, and Features:
®
vent plumbing systems, Clean-Seal plugs thread • Works in both plastic and cast-iron test tees
into a standard test tee. The bladder is inflated and • Natural rubber body provides a leak-free seal
then water is introduced into the pipe. Upon test • High-impact ABS threads for maximum durability
completion, deflate the bladder; water travels down
the pipe, eliminating test water backsplash. • Removable/replaceable tire inflation valve fitting
CLEAN-SEAL
PART NOMINAL MAXIMUM INFLATION PRODUCT DEFLATED DEFLATED INFLATION
NUMBER SIZE BACK PRESSURE PRESSURE WEIGHT LENGTH DIAMETER THREAD
1.5" 13 psi 30 ft. 30 psi .15 lbs 4.75" 1.5"
271508 1/8"
(40 mm) (0,9 bar) (9.1 M) (2,1 bar) (0.07 kg) (121 mm) (38 mm)
2" 13 psi 30 ft. 35 psi .3 lbs 5.81" 2.38"
271705 1/8"
(50 mm) (0,9 bar) (9.1 M) (2,4 bar) (0.14 kg) (150 mm) (60 mm)
3" 13 psi 30 ft. 35 psi .8 lbs 7.38" 3.5"
271713 1/4"
(75 mm) (0,9 bar) (9.1 M) (2,4 bar) (0.36 kg) (188 mm) (89 mm)
4" 13 psi 30 ft. 35 psi 1.3 lbs 8.5" 4.5"
271721 1/4"
(100 mm) (0,9 bar) (9.1 M) (2,4 bar) (0.59 kg) (215 mm) (115 mm)
6" 13 psi 30 ft. 25 psi 3.5 lbs 11" 6.63"
271758 1/4"
(150 mm) (0,9 bar) (9.1 M) (1,7 bar) (1.59 kg) (280 mm) (168 mm)
Clean-Seal Application
®
Simply thread into test tee and
inflate (for maximum sealing
performance, apply thread seal
tape to the threads before use).
Inflated (test) Deflated (test release)
7