41-46 HEATING AND AIR CONDITIONING - A/C COMPRESSOR
A/C COMPRESSOR
OVERHAUL
NOTICE:
• Work with dedicated service systems applicable to the A/C system of this model.
• Since leakage is common in the A/C system, keep the workspace well ventilated.
• Seal the disconnected pipes with plugs, to prevent impurities from entering the system.
1. Switch off all electrical units and the ignition
2. Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
Charging- Battery, Replacement")
3. Collect the refrigerant (Refer to "Chapter41 Heating And Air Conditioning -
Refrigerant, Replacement")
4. Remove the stabilizer bar (Refer to "Chapter 31 Front Suspension - Stabilizer Bar,
Replacement")
5. Remove the compressor
(a). Disconnect the connector.
fuwx41063
(b). Unscrew the fastening bolts connected to
the compressor pipe and disconnect the
pipe.
fuwx41064