Page 1333 - Foton Workshop Manual - Aumark (BJ1099)
P. 1333
HEATING AND AIR CONDITIONING - CONDENSER 41-53
ONBOARD CHECKING
1. Check the condenser assembly
(a). If the condenser fin is dirty, clean it with water and blow it dry.
NOTICE:
When cleaning, don't damage the fin.
(b). If the condenser fin is bent or distorted, groom it with fin comb.
2. Check for refrigerant leakage in the condenser assembly
(a). Check for leakage at the connector with leakage detector.
(b). If any, check the connector Torque and O-ring.
(c). Check for leakage in the condenser fin and if any, replace the condenser assembly
if needed.
OVERHAUL
NOTICE:
• The condenser is a heat exchanger with many refined and fragile parts in terms of
structure and material. Be careful when disassembling it and prevent it from falling,
impact or scratch.
• Use a new O-ring and apply some coolant before installation.
• Since leakage is common in the A/C system, keep the workspace well ventilated.
• Seal the disconnected pipes with plugs, to prevent impurities from entering the system.
1. Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
Charging - Battery, Replacement") 41
2. Collect the refrigerant (Refer to "Chapter41 Heating And Air Conditioning -
Refrigerant, Replacement")
3. Remove the front grille (Refer to"Chapter 56 Interior/Exterior Trims - Front Grille,
Replacement")
4. Remove the condenser
(a). Disconnect the connector of the horn.
fuwx41032
Page 1333