HEATING AND AIR CONDITIONING - A/C VALVE MOTOR 41-65
A/C VALVE MOTOR
REPLACEMENT
1. Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
Charging- Battery, Replacement")
2. Remove the instrument panel (Refer to "Chapter 52 Instrument Panel & Auxiliary
Instrument Panel - Instrument Panel, Replacement")
3. Remove the circulation valve motor
(a). Disconnect the connector of the circulation
valve motor.
(b). Unscrew the fastening bolts of the 41
circulation valve motor and remove the
circulation valve motor.
Page 1345