ENGINE MECHANICAL SYSTEM - ELECTRIC SYSTEM                      12C-187

                                                             (c).   Disconnect the 1-ear clamp on the solenoid
                                                                   valve vacuum pipe subassembly (arrow
                                                                   direction) and move aside the solenoid
                                                                   valve vacuum pipe subassembly.










                                                fuwx12C489


                                                             (d).   Press the positioning clip in the arrow         12C
                                                                   direction,  and  remove  the  intake  pipe
                                                                   flapper control valve.












                                                fuwx12C490


                                                             8.    Install the intake pipe flapper control valve
                                                             (a).   Press the positioning clip in the arrow
                                                                   direction, and Install the intake pipe flapper
                                                                   control valve.










                                                fuwx12C491


                                                             (b).   Fit a new 1-ear clamp (arrow direction) onto
                                                                   the canister solenoid valve vacuum pipe
                                                                   subassembly.