Page 2278 - Foton Workshop Manual - Sauvana
P. 2278

62-226                      DIAGNOSIS-HEATER & AIR CONDITIONING


           Diagnosis Procedure


           1.     Check fuse


           (a).   Disconnect the battery negative cable.


                                                      (b).    Check the fuse in fuse box within engine
                                                              housing:
               Disconnect            Normal
                                                                  • F20(7.5A)
                                                       (c).   Check the fuse in fuse box within house:
                                                                  • F17(5A)
                                                                  • F20(7.5A)
                                                                  • F33(5A)
                                                                  • F41(5A)
                                           fuwx62605

           Is the result normal?
           Yes>To step 2.
           No >Replace the fuse.


           2.     Check air condition compressor relay


           (a).   Disconnect the battery negative cable.
           (b).   Unplug the start-up tripping relay R04.


                                                      (c).    Check the start-up tripping relay R04.
                                                                  Standard resistance:

                                                                                Connect by  Specified
                                                                Conditions
                                                                                  multimeter       value
                                                                Ordinary state        1-2         Existed

                                                               Apply the power
                                                                supply voltage
                                                                 between the          3-4          < 2Ω
                                                               No. 1 and No. 2
                                                                     pin
           Is the result normal?
           Yes>To step 3.
           No >Replace the air conditioning compressor relay to validate again whether this fault
                   exists or not.