Page 34 - Cummins INSITE Overview (2018)
P. 34
ECM Password Removal (Zap-IT)
To remove ECM and OEM passwords:
– Select Tools> ECM Password Removal... on the menu bar. The ECM
Password Removal window will appear. This window is also called
the ZAP-IT window.
– Select the type of ECM Passwords to be removed.
– Select ZAP-IT. The ECM Password Removal Confirmation window will
appear.
– Select Yes and follow the prompts to remove the ECM passwords.
– The ECM Password Removal window will display the number of counts
remaining, if any.
– Select Cancel to close the ECM Password Removal screen.
Zap-IT passwords are entered using the
Cummins License Configuration Tool (LCT)
Zap-IT Counts can be obtained from local
Distributors
34